Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
40
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0193 # 02 Y:1990 | 02 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,252 | $12,000 | Not Implemented |
MA0193 # 01 Y:1990 | 01 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $984 | $426 | Implemented |
MA0193 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $173 | $348 | Not Implemented |
MA0193 # 03 Y:1990 | 03 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $40,469 | $5,400 | Implemented |
KU0323 # 03 Y:1990 | 03 | 1990 | INSULATE BARE EQUIPMENT | $201 | $120 | Implemented |
KU0323 # 02 Y:1990 | 02 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $560 | $220 | Not Implemented |
MA0193 # 05 Y:1990 | 05 | 1990 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,037 | $2,609 | Not Implemented |
KU0323 # 01 Y:1990 | 01 | 1990 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $832 | $987 | Not Implemented |
MA0193 # 06 Y:1990 | 06 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,438 | $0 | Implemented |
MA0181 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $82 | $75 | Implemented |
MA0181 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,640 | $90,296 | Implemented |
MA0181 # 02 Y:1990 | 02 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $29,219 | $0 | Not Implemented |
MA0181 # 01 Y:1990 | 01 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,610 | $0 | Implemented |
TN0402 # 04 Y:1990 | 04 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,440 | $0 | Implemented |
TN0402 # 09 Y:1990 | 09 | 1990 | IMPROVE LUBRICATION PRACTICES | $57 | $30 | Not Implemented |
TN0402 # 07 Y:1990 | 07 | 1990 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $780 | $660 | Not Implemented |
TN0402 # 08 Y:1990 | 08 | 1990 | DISCONNECT BALLASTS | $96 | $0 | Implemented |
TN0402 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,474 | $4,140 | Implemented |
TN0402 # 06 Y:1990 | 06 | 1990 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $880 | $500 | Implemented |
TN0402 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,428 | $960 | Implemented |
TN0402 # 01 Y:1990 | 01 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $4,123 | $11,116 | Implemented |
TN0402 # 05 Y:1990 | 05 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $925 | $0 | Implemented |
MA0174 # 04 Y:1990 | 04 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,525 | $120 | Implemented |
MA0174 # 01 Y:1990 | 01 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $388 | $649 | Not Implemented |
MA0174 # 06 Y:1990 | 06 | 1990 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $24,108 | $27,827 | Not Implemented |