Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0868 # 07 Y:2013 | 07 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $7,022 | $1,140 | Implemented |
OK0868 # 04 Y:2013 | 04 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,792 | $1,851 | Implemented |
OK0868 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,572 | $7,700 | Implemented |
OK0868 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,347 | $750 | Implemented |
OK0868 # 06 Y:2013 | 06 | 2013 | INSTALL SET-BACK TIMERS | $3,871 | $606 | Implemented |
OK0868 # 09 Y:2013 | 09 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $287 | $456 | Implemented |
OK0868 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,457 | $13,371 | Implemented |
OK0868 # 13 Y:2013 | 13 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $33,598 | $0 | Implemented |
AM0430 # 04 Y:2003 | 04 | 2003 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,840 | $700 | Implemented |
AM0430 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,300 | $0 | Implemented |
AM0430 # 06 Y:2003 | 06 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $850 | $77 | Implemented |
AM0430 # 07 Y:2003 | 07 | 2003 | REUSE RAGS UNTIL COMPLETELY SOILED | $795 | $0 | Implemented |
AM0430 # 10 Y:2003 | 10 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $180 | $0 | Implemented |
AM0265 # 06 Y:1996 | 06 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $200 | $300 | Implemented |
AM0265 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,550 | $240 | Implemented |
AM0265 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,260 | $760 | Implemented |
AM0265 # 01 Y:1996 | 01 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,100 | $750 | Implemented |
AM0195 # 02 Y:1993 | 02 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,500 | $0 | Implemented |
AM0195 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $21,340 | $21,050 | Implemented |
AM0195 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $330 | $50 | Implemented |
AM0195 # 05 Y:1993 | 05 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,590 | $4,420 | Implemented |
AM0195 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $680 | $580 | Implemented |
AM0192 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $210 | $240 | Implemented |
AM0192 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,950 | $12,850 | Implemented |
AM0069 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,360 | $1,000 | Implemented |