IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

75

matching recommendations
Reset
SIC 382 Measuring And Controlling Devices
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0021 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $106 $3,890 Implemented
WV0021 # 03 Y:1994 03 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $1,191 $490 Not Implemented
WV0021 # 04 Y:1994 04 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $340 $560 Not Implemented
WV0021 # 06 Y:1994 06 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $2,619 $0 Not Implemented
WV0021 # 07 Y:1994 07 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $690 $0 Implemented
WV0021 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $215 $280 Not Implemented
HO0039 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $284 $674 Not Implemented
HO0039 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $53 $200 Not Implemented
HO0039 # 04 Y:1993 04 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $28 $99 Not Implemented
HO0039 # 05 Y:1993 05 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,224 $4,000 Not Implemented
HO0039 # 06 Y:1993 06 1993 INSTALL OCCUPANCY SENSORS $608 $400 Not Implemented
HO0039 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,561 $1,262 Not Implemented
ST0024 # 09 Y:1985 09 1985 INSULATE BARE EQUIPMENT $44 $26 Implemented
ST0024 # 08 Y:1985 08 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,190 $1,428 Not Implemented
ST0024 # 07 Y:1985 07 1985 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $1,678 $0 Implemented
ST0024 # 06 Y:1985 06 1985 INSTALL AUTOMATIC STACK DAMPER $200 $2,550 Not Implemented
ST0024 # 05 Y:1985 05 1985 CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES $2,549 $3,000 Not Implemented
ST0024 # 04 Y:1985 04 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $893 $112 Implemented
ST0024 # 03 Y:1985 03 1985 RECOVER WASTE HEAT FROM EQUIPMENT $1,844 $1,600 Not Implemented
ST0024 # 02 Y:1985 02 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $65 $95 Not Implemented
ST0024 # 01 Y:1985 01 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $196 $0 Implemented
ST0024 # 10 Y:1985 10 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $7,186 $1,900 Implemented
ST0024 # 11 Y:1985 11 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,038 $2,186 Implemented
ST0024 # 12 Y:1985 12 1985 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $8,820 $0 Not Implemented
ST0024 # 13 Y:1985 13 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,126 $76 Implemented