Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
276
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0071 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,163 | $945 | Implemented |
LM0071 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $1,330 | $1,200 | Implemented |
LM0071 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,879 | $0 | Implemented |
LM0071 # 06 Y:2004 | 06 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $99,668 | $24,000 | Not Implemented |
LM0071 # 10 Y:2004 | 10 | 2004 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $84,322 | $100,000 | Implemented |
LM0071 # 09 Y:2004 | 09 | 2004 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $252,500 | $35,000 | Not Implemented |
LM0071 # 07 Y:2004 | 07 | 2004 | MODIFY CURRENT INCENTIVE PROGRAM | $3,000 | $300 | Implemented |
LM0071 # 08 Y:2004 | 08 | 2004 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $214,912 | $3,000 | Not Implemented |
SD0311 # 01 Y:2003 | 01 | 2003 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $10,146 | $19,000 | Not Implemented |
SD0311 # 02 Y:2003 | 02 | 2003 | USE PHOTOCELL CONTROLS | $3,064 | $2,000 | Implemented |
SD0311 # 03 Y:2003 | 03 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $501 | $0 | Implemented |
SD0311 # 04 Y:2003 | 04 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,622 | $5,000 | Implemented |
SD0311 # 05 Y:2003 | 05 | 2003 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $31,104 | $0 | Not Implemented |
SF0231 # 03 Y:2002 | 03 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $20,883 | $15,071 | n/a |
SF0231 # 01 Y:2002 | 01 | 2002 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,403 | $913 | n/a |
SF0231 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,732 | $4,138 | n/a |
SF0231 # 15 Y:2002 | 15 | 2002 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,241 | $7,875 | n/a |
SF0231 # 14 Y:2002 | 14 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,215 | $15,574 | n/a |
SF0231 # 13 Y:2002 | 13 | 2002 | RECYCLE CLEANING SOLVENT AND REUSE | $298,889 | $560,000 | n/a |
SF0231 # 08 Y:2002 | 08 | 2002 | USE PHOTOCELL CONTROLS | $7,529 | $8,040 | n/a |
SF0231 # 12 Y:2002 | 12 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $73,389 | $280,599 | n/a |
SF0231 # 11 Y:2002 | 11 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,491 | $6,516 | n/a |
SF0231 # 10 Y:2002 | 10 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,934 | $27,835 | n/a |
SF0231 # 09 Y:2002 | 09 | 2002 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,658 | $8,500 | n/a |
SF0231 # 07 Y:2002 | 07 | 2002 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $5,916 | $5,753 | n/a |