Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2004 |
Principal Product | Electronic Test Equipment |
NAICS | 334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals |
SIC | 3825 - Instruments To Measure Electricity |
Sales | $100,000,000-$500,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 300 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,315,501 | 12,590,092 | kWh | $0.10 |
Electricity Demand | $289,368 | 13,848 | kW-months/year | $20.90 |
Electricity Fees | $44,128 | - | $ | - |
TOTAL ENERGY COSTS | $1,648,997 | |||
RECOMMENDED SAVINGS* | $756,144 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $104,694 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,818 Cost: $1,176 |
$3,100 | 30,069 | $718 | 55 | - | - | - | - | - | - |
$3,100 30,069 kWh |
$718 55 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $80,552 Cost: $121,600 |
$65,680 | 637,216 | $14,872 | 1,145 | - | - | - | - | - | - |
$65,680 637,216 kWh |
$14,872 1,145 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $8,163 Cost: $945 |
$6,960 | 67,531 | $1,203 | 92 | - | - | - | - | - | - |
$6,960 67,531 kWh |
$1,203 92 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,330 Cost: $1,200 |
$1,050 | 3,728 | $280 | 22 | - | - | - | - | - | - |
$1,050 3,728 kWh |
$280 22 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $7,879 Cost: - |
$5,706 | 55,518 | $2,173 | 168 | - | - | - | - | - | - |
$5,706 55,518 kWh |
$2,173 168 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $99,668 Cost: $24,000 |
$107,312 | 1,195,672 | - | - | $7,956 | 2,975,544 | $(-15,600) | - | - | - |
$107,312 1,195,672 kWh |
- - kW-months/year |
$7,956 2,975,544 Tgal |
$(-15,600) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.421 MODIFY CURRENT INCENTIVE PROGRAM |
Savings: $3,000 Cost: $300 |
- | - | - | - | - | - | - | - | $3,000 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $214,912 Cost: $3,000 |
- | - | - | - | - | - | $214,912 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$214,912 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.522 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE |
Savings: $252,500 Cost: $35,000 |
- | - | - | - | - | - | - | - | $252,500 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$252,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $84,322 Cost: $100,000 |
$59,704 | 400,336 | $24,618 | 1,968 | - | - | - | - | - | - |
$59,704 400,336 kWh |
$24,618 1,968 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $756,144 Cost: $287,221 |
$249,512 | 2,390,070 | $43,864 | 3,450 | $7,956 | 2,975,544 | $199,312 | - | $255,500 | - | $249,512 2,390,070 kWh |
$43,864 3,450 kW-months/year |
$7,956 2,975,544 Tgal |
$199,312 - $ |
$255,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $104,694 Cost: $102,445 |
$73,420 | 527,113 | $28,274 | 2,250 | - | - | - | - | $3,000 | - | $73,420 527,113 kWh |
$28,274 2,250 kW-months/year |
- - Tgal |
- - $ |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes |