Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0497 # 02 Y:1996 | 02 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,460 | $300 | Not Implemented |
UD0497 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,760 | $13,724 | Implemented |
UD0497 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,035 | $20,230 | Implemented |
UD0497 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,514 | $1,500 | Not Implemented |
TN0588 # 04 Y:1996 | 04 | 1996 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $610 | $1,800 | Not Implemented |
TN0588 # 03 Y:1996 | 03 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,760 | $5,300 | Implemented |
TN0588 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $290 | $845 | Implemented |
TN0588 # 02 Y:1996 | 02 | 1996 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $14,500 | $13,000 | Not Implemented |
TN0588 # 05 Y:1996 | 05 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $545 | $0 | Not Implemented |
TN0588 # 01 Y:1996 | 01 | 1996 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $45,192 | $51,320 | Implemented |
NC0095 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,473 | $6,046 | Implemented |
NC0095 # 08 Y:1996 | 08 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,022 | $320 | Not Implemented |
NC0095 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $195 | $90 | Implemented |
NC0095 # 07 Y:1996 | 07 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $367 | $367 | Not Implemented |
NC0095 # 09 Y:1996 | 09 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $38 | $100 | Not Implemented |
NC0095 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $439 | $400 | Not Implemented |
NC0095 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $549 | $2,100 | Not Implemented |
NC0095 # 02 Y:1996 | 02 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $641 | $0 | Not Implemented |
NC0095 # 01 Y:1996 | 01 | 1996 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,105 | $5,000 | Implemented |
SD0136 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,889 | $3,260 | Implemented |
SD0135 # 08 Y:1996 | 08 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $100 | $150 | Implemented |
SD0135 # 07 Y:1996 | 07 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $100 | $0 | Implemented |
SD0135 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $2,105 | $2,127 | Implemented |
SD0135 # 05 Y:1996 | 05 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $17,409 | $20,135 | Implemented |
SD0136 # 08 Y:1996 | 08 | 1996 | REDUCE SCRAP PRODUCTION | $56,160 | $0 | Implemented |