Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 384 | Medical Instruments And Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0241 # 02 Y:2024 | 02 | 2024 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $7,985 | $4,420 | n/a |
DL0241 # 03 Y:2024 | 03 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,075 | $5,000 | n/a |
DL0241 # 01 Y:2024 | 01 | 2024 | RECOVER WASTE HEAT FROM EQUIPMENT | $30,655 | $117,000 | n/a |
DL0075 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,000 | $5,000 | Not Implemented |
DL0075 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,400 | $740 | Not Implemented |
DL0075 # 05 Y:2011 | 05 | 2011 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $6,900 | $9,250 | Not Implemented |
DL0075 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $719 | $1,100 | Not Implemented |
DL0075 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,281 | $5,000 | Not Implemented |
DL0075 # 04 Y:2011 | 04 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,900 | $2,920 | Not Implemented |
DL0075 # 03 Y:2011 | 03 | 2011 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $14,910 | $47,500 | Not Implemented |
DL0075 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,000 | $10,910 | Not Implemented |
DL0075 # 01 Y:2011 | 01 | 2011 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $17,900 | $6,660 | Not Implemented |
DL0058 # 06 Y:2010 | 06 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $10,400 | $100 | Not Implemented |
DL0058 # 12 Y:2010 | 12 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,140 | $5,050 | Not Implemented |
DL0058 # 11 Y:2010 | 11 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,215 | $2,500 | Not Implemented |
DL0058 # 10 Y:2010 | 10 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,110 | $18,280 | Not Implemented |
DL0058 # 09 Y:2010 | 09 | 2010 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $4,200 | $10,000 | Not Implemented |
DL0058 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,000 | $7,644 | Implemented |
DL0058 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,080 | $6,300 | Not Implemented |
DL0058 # 05 Y:2010 | 05 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,800 | $250 | Implemented |
DL0058 # 04 Y:2010 | 04 | 2010 | DISCONNECT BALLASTS | $12,500 | $350 | Not Implemented |
DL0058 # 03 Y:2010 | 03 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $143,000 | $4,268 | Implemented |
DL0058 # 02 Y:2010 | 02 | 2010 | INSTALL FOSSIL FUEL MAKE-UP AIR UNIT | $95,200 | $250,000 | Not Implemented |
DL0058 # 01 Y:2010 | 01 | 2010 | REDUCE VENTILATION AIR | $152,300 | $500,000 | Not Implemented |
DL0026 # 05 Y:2008 | 05 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,327 | $640 | Not Implemented |