Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsSIC | 3841 | Surgical And Medical Instruments |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0068 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $1,210 | $2,719 | Not Implemented |
UA0068 # 05 Y:2011 | 05 | 2011 | DISCONNECT BALLASTS | $3,015 | $607 | Not Implemented |
UA0068 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,451 | $46,341 | Implemented |
UA0068 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,210 | $4,238 | Not Implemented |
UA0068 # 02 Y:2011 | 02 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $15,438 | $13,988 | Implemented |
UA0068 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $16,400 | $5,100 | Implemented |
LE0325 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,249 | $15,615 | Implemented |
LE0325 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,654 | $1,955 | Not Implemented |
LE0325 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,815 | $15,840 | Not Implemented |
LE0325 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,946 | $6,396 | Implemented |
LE0325 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,438 | $0 | Not Implemented |
LE0325 # 02 Y:2011 | 02 | 2011 | USE SOLAR HEAT TO HEAT WATER | $52,419 | $21,000 | Not Implemented |
LE0325 # 01 Y:2011 | 01 | 2011 | USE HEAT PUMP FOR SPACE CONDITIONING | $148,547 | $900,000 | Not Implemented |
MI0208 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,789 | $2,400 | Implemented |
MI0208 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,355 | $1,320 | Implemented |
MI0208 # 05 Y:2011 | 05 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,241 | $20,530 | Not Implemented |
MI0208 # 04 Y:2011 | 04 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $16,075 | $2,550 | Not Implemented |
MI0208 # 03 Y:2011 | 03 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $25,727 | $48,170 | Implemented |
MI0208 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,143 | $16,918 | Implemented |
MI0208 # 01 Y:2011 | 01 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $40,370 | $292,600 | Implemented |
MI0207 # 03 Y:2011 | 03 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $61,926 | $2,550 | Implemented |
MI0207 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,650 | $9,200 | Not Implemented |
MI0207 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,901 | $1,320 | Implemented |
MI0207 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $33,207 | $8,474 | Not Implemented |