Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,558

matching recommendations
Reset
SIC 39 Miscellaneous Manufacturing Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0281 # 09 Y:2005 09 2005 MINIMIZE WATER USAGE $903 $1,320 Not Implemented
BD0282 # 01 Y:2005 01 2005 USE RADIANT HEATER FOR SPOT HEATING $14,504 $9,200 Not Implemented
BD0282 # 02 Y:2005 02 2005 PREHEAT COMBUSTION AIR WITH WASTE HEAT $7,913 $12,000 Not Implemented
BD0282 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,962 $3,545 Not Implemented
BD0282 # 04 Y:2005 04 2005 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $6,896 $15,000 Not Implemented
BD0282 # 05 Y:2005 05 2005 PREHEAT COMBUSTION AIR WITH WASTE HEAT $6,787 $5,000 Not Implemented
BD0282 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,439 $3,200 Not Implemented
BD0282 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $1,696 $375 Not Implemented
BD0282 # 08 Y:2005 08 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,494 $3,200 Not Implemented
BD0282 # 09 Y:2005 09 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $544 $0 Not Implemented
BD0282 # 10 Y:2005 10 2005 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $212 $450 Not Implemented
BD0278 # 01 Y:2005 01 2005 USE RADIANT HEATER FOR SPOT HEATING $4,205 $16,000 Implemented
BD0278 # 02 Y:2005 02 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,770 $3,597 Implemented
BD0278 # 03 Y:2005 03 2005 INSTALL OCCUPANCY SENSORS $1,527 $525 Implemented
BD0278 # 04 Y:2005 04 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,148 $2,000 Implemented
BD0278 # 05 Y:2005 05 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $552 $450 Not Implemented
BD0278 # 06 Y:2005 06 2005 RECOVER AND REUSE COOLING WATER $1,459 $5,000 Implemented
BD0279 # 01 Y:2005 01 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $25,688 $8,400 Not Implemented
BD0279 # 02 Y:2005 02 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,079 $3,170 Not Implemented
BD0279 # 03 Y:2005 03 2005 INSTALL OCCUPANCY SENSORS $846 $150 Not Implemented
BD0279 # 04 Y:2005 04 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $678 $480 Not Implemented
BD0275 # 01 Y:2005 01 2005 USE RADIANT HEATER FOR SPOT HEATING $40,891 $81,000 Not Implemented
BD0275 # 02 Y:2005 02 2005 INSTALL REPLACEMENT DOORS $13,598 $40,000 Not Implemented
BD0275 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,985 $421 Implemented
BD0275 # 04 Y:2005 04 2005 INSTALL OCCUPANCY SENSORS $5,242 $3,150 Implemented