Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,558

matching recommendations
Reset
SIC 39 Miscellaneous Manufacturing Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0306 # 07 Y:1994 07 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $757 $434 Implemented
MO0115 # 01 Y:1994 01 1994 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $9,743 $365 Not Implemented
MO0115 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,835 $11,383 Not Implemented
MO0115 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,487 $1,380 Not Implemented
MO0115 # 04 Y:1994 04 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,705 $3,453 Not Implemented
MO0115 # 05 Y:1994 05 1994 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $8 $20 Not Implemented
MO0115 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,443 $911 Implemented
MO0115 # 07 Y:1994 07 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,433 $50 Not Implemented
MO0115 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,743 $9,239 Not Implemented
MO0115 # 09 Y:1994 09 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $807 $373 Not Implemented
KU0423 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,156 $1,663 Not Implemented
KU0423 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $240 $300 Implemented
KU0423 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $80 $125 Implemented
KU0423 # 04 Y:1994 04 1994 INSTALL TIMERS AND/OR THERMOSTATS $904 $900 Implemented
KU0423 # 05 Y:1994 05 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $229 $477 Not Implemented
KU0423 # 06 Y:1994 06 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $187 $135 Not Implemented
DS0001 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,990 $12,650 Not Implemented
DS0001 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $70 $120 Not Implemented
DS0001 # 03 Y:1994 03 1994 INSTALL STORM WINDOWS AND DOORS $140 $280 Not Implemented
DS0001 # 04 Y:1994 04 1994 INSTALL STORM WINDOWS AND DOORS $1,130 $8,200 Not Implemented
DS0001 # 05 Y:1994 05 1994 INSTALL STORM WINDOWS AND DOORS $740 $20 Not Implemented
DS0001 # 06 Y:1994 06 1994 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $4,760 $44,950 Not Implemented
DS0001 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $130 $690 Not Implemented
DS0001 # 08 Y:1994 08 1994 USE RADIANT HEATER FOR SPOT HEATING $9,150 $34,800 Not Implemented
UF0076 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $935 $112 Implemented