Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,558
matching recommendationsSIC | 39 | Miscellaneous Manufacturing Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0016 # 05 Y:1991 | 05 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $41 | $0 | Implemented |
MO0016 # 06 Y:1991 | 06 | 1991 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $18 | $3 | Implemented |
MO0016 # 07 Y:1991 | 07 | 1991 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $10 | $210 | Implemented |
GT0415 # 01 Y:1990 | 01 | 1990 | REDUCE VENTILATION AIR | $216 | $2,220 | Implemented |
GT0415 # 02 Y:1990 | 02 | 1990 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,460 | $0 | Implemented |
GT0415 # 03 Y:1990 | 03 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $410 | $0 | Not Implemented |
GT0415 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $627 | $254 | Implemented |
GT0415 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $630 | $200 | Implemented |
GT0415 # 06 Y:1990 | 06 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $830 | $3,650 | Not Implemented |
GT0415 # 07 Y:1990 | 07 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $573 | $2,400 | Not Implemented |
TN0410 # 01 Y:1990 | 01 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $25,287 | $29,907 | Implemented |
TN0410 # 02 Y:1990 | 02 | 1990 | INSTALL SET-BACK TIMERS | $11,948 | $0 | Implemented |
TN0410 # 03 Y:1990 | 03 | 1990 | OPTIMIZE PLANT POWER FACTOR | $13,343 | $44,500 | Implemented |
TN0410 # 04 Y:1990 | 04 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $11,650 | $7,440 | Not Implemented |
TN0410 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,844 | $930 | Implemented |
TN0410 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $9,891 | $7,200 | Not Implemented |
TN0410 # 07 Y:1990 | 07 | 1990 | IMPROVE LUBRICATION PRACTICES | $3,261 | $0 | Not Implemented |
TN0410 # 08 Y:1990 | 08 | 1990 | ADJUST VENTS TO MINIMIZE ENERGY USE | $2,515 | $3,600 | Implemented |
TN0410 # 09 Y:1990 | 09 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,602 | $0 | Implemented |
TN0410 # 10 Y:1990 | 10 | 1990 | ADJUST VENTS TO MINIMIZE ENERGY USE | $975 | $1,545 | Not Implemented |
TN0403 # 01 Y:1990 | 01 | 1990 | REDUCE EXCESS STEAM BLEEDING | $5,335 | $1,280 | Implemented |
TN0403 # 02 Y:1990 | 02 | 1990 | INSULATE BARE EQUIPMENT | $4,167 | $2,442 | Not Implemented |
TN0403 # 03 Y:1990 | 03 | 1990 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $1,886 | $4,964 | Not Implemented |
TN0403 # 04 Y:1990 | 04 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $501 | $356 | Implemented |