Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
81
matching recommendationsSIC | 39 | Miscellaneous Manufacturing Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0646 # 08 Y:2011 | 08 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $150 | $40 | Implemented |
CO0646 # 07 Y:2011 | 07 | 2011 | INSTALL WIND POWERED ELECTRIC GENERATOR | $270 | $5,260 | Not Implemented |
CO0646 # 03 Y:2011 | 03 | 2011 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $2,120 | $10,000 | Implemented |
CO0646 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,270 | $7,320 | Not Implemented |
CO0646 # 04 Y:2011 | 04 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,080 | $14,690 | Not Implemented |
CO0646 # 01 Y:2011 | 01 | 2011 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,270 | $62,380 | Not Implemented |
CO0646 # 05 Y:2011 | 05 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,910 | $35,000 | Not Implemented |
CO0646 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,340 | $2,730 | Implemented |
CO0399 # 03 Y:1997 | 03 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $490 | $1,660 | Not Implemented |
CO0399 # 06 Y:1997 | 06 | 1997 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $45,100 | $13,100 | Implemented |
CO0399 # 04 Y:1997 | 04 | 1997 | IMPROVE COMBUSTION CONTROL CAPABILITY | $320 | $750 | Implemented |
CO0399 # 05 Y:1997 | 05 | 1997 | USE A RAG RECYCLE SERVICE | $480 | $0 | Implemented |
CO0399 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,240 | $600 | Implemented |
CO0399 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $937 | $2,504 | Not Implemented |
CO0399 # 07 Y:1997 | 07 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $12,870 | $1,100 | Not Implemented |
CO0396 # 06 Y:1997 | 06 | 1997 | INSTALL MAGAZINES FOR TEMPORARY STORAGE | $12,600 | $3,600 | Implemented |
CO0396 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $100 | $0 | Implemented |
CO0396 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $691 | $1,050 | Implemented |
CO0396 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $270 | $1,000 | Implemented |
CO0396 # 04 Y:1997 | 04 | 1997 | UPGRADE OBSOLETE EQUIPMENT | $180 | $540 | Implemented |
CO0396 # 01 Y:1997 | 01 | 1997 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,020 | $1,690 | Implemented |
CO0379 # 02 Y:1996 | 02 | 1996 | INSTALL CONTINUOUS LUBRICATION EQUIPMENT | $32,640 | $3,000 | Implemented |
CO0379 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $37,440 | $48,250 | Implemented |
CO0379 # 03 Y:1996 | 03 | 1996 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $29,180 | $270 | Implemented |
CO0379 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,307 | $5,236 | Implemented |