Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

16

matching recommendations
Reset
SIC 39 Miscellaneous Manufacturing Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0087 # 01 Y:2012 01 2012 KEEP EQUIPMENT CLEAN $378,860 $370,000 Implemented
DL0087 # 03 Y:2012 03 2012 USE RADIANT HEATER FOR SPOT HEATING $410,000 $1,200,000 Implemented
DL0087 # 04 Y:2012 04 2012 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $20,000 $78,000 Implemented
DL0087 # 05 Y:2012 05 2012 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $11,900 $14,000 Implemented
DL0087 # 08 Y:2012 08 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,200 $5,400 Implemented
LE0143 # 03 Y:2002 03 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,286 $0 Implemented
LE0143 # 06 Y:2002 06 2002 USE SYNTHETIC LUBRICANT $793 $400 Implemented
ST0017 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,863 $953 Implemented
ST0017 # 03 Y:1985 03 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $302 $46 Implemented
ST0017 # 05 Y:1985 05 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $13,133 $1,900 Implemented
ST0017 # 06 Y:1985 06 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,200 $104 Implemented
ST0017 # 07 Y:1985 07 1985 INSULATE BARE EQUIPMENT $1,765 $1,800 Implemented
ST0017 # 08 Y:1985 08 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $20,755 $1,900 Implemented
ST0017 # 09 Y:1985 09 1985 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $605 $0 Implemented
ST0017 # 10 Y:1985 10 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,307 $1,400 Implemented
ST0017 # 11 Y:1985 11 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $439 $497 Implemented