Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
80
matching recommendationsSIC | 39 | Miscellaneous Manufacturing Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0535 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $9,820 | $6,420 | Implemented |
CO0535 # 03 Y:2003 | 03 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,160 | $15,760 | Implemented |
CO0535 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,340 | $750 | Implemented |
CO0535 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,250 | $9,690 | Implemented |
CO0535 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $1,100 | $2,820 | Not Implemented |
CO0535 # 07 Y:2003 | 07 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $670 | $1,210 | Not Implemented |
CO0535 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $411 | $112 | Implemented |
CO0535 # 09 Y:2003 | 09 | 2003 | MODIFY WORKLOAD | $30,340 | $6,600 | Not Implemented |
CO0535 # 01 Y:2003 | 01 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $30,840 | $6,420 | Not Implemented |
MS0234 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $205 | $416 | Not Implemented |
MS0234 # 07 Y:2003 | 07 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $40 | $43 | Not Implemented |
MS0234 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,991 | $10,304 | Not Implemented |
MS0234 # 06 Y:2003 | 06 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $64 | $115 | Implemented |
MS0234 # 05 Y:2003 | 05 | 2003 | PAY BILLS ON TIME TO AVOID LATE FEES | $92 | $100 | Not Implemented |
MS0234 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,578 | $99 | Implemented |
MS0234 # 03 Y:2003 | 03 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $237 | $0 | Implemented |
LL0177 # 08 Y:2003 | 08 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $448 | $40 | Not Implemented |
LL0177 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $30 | $43 | Implemented |
LL0177 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,096 | $665 | Not Implemented |
LL0177 # 05 Y:2003 | 05 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,131 | $235 | Not Implemented |
LL0177 # 04 Y:2003 | 04 | 2003 | INSULATE BARE EQUIPMENT | $1,253 | $1,600 | Implemented |
LL0177 # 03 Y:2003 | 03 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,193 | $316 | Implemented |
LL0177 # 02 Y:2003 | 02 | 2003 | PAY UTILITY BILLS ON TIME | $2,710 | $30 | Implemented |
LL0177 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,804 | $4,160 | Implemented |
WV0268 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,769 | $20,880 | Implemented |