Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
35
matching recommendationsSIC | 39 | Miscellaneous Manufacturing Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0618 # 02 Y:2008 | 02 | 2008 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $19,720 | $10,000 | Implemented |
CO0618 # 03 Y:2008 | 03 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $5,170 | $61,600 | Implemented |
CO0618 # 04 Y:2008 | 04 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,950 | $42,300 | Implemented |
CO0618 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $1,780 | $50,000 | Implemented |
CO0618 # 06 Y:2008 | 06 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,050 | $640 | Implemented |
CO0618 # 01 Y:2008 | 01 | 2008 | USE POWER DURING OFF-PEAK PERIODS | $15,050 | $0 | Not Implemented |
SF0365 # 01 Y:2008 | 01 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $447 | $384 | Implemented |
SF0365 # 02 Y:2008 | 02 | 2008 | USE PHOTOCELL CONTROLS | $6,469 | $11,199 | Not Implemented |
SF0365 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,182 | $7,436 | Not Implemented |
SF0365 # 04 Y:2008 | 04 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $12,886 | $68,250 | Implemented |
UW0020 # 01 Y:2008 | 01 | 2008 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $115,054 | $172,581 | Not Implemented |
UW0020 # 03 Y:2008 | 03 | 2008 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $8,002 | $34,238 | Not Implemented |
UW0020 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,000 | $24,547 | Not Implemented |
UW0020 # 05 Y:2008 | 05 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $403 | $145 | Implemented |
UW0020 # 04 Y:2008 | 04 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $1,828 | $450 | Implemented |
UW0020 # 06 Y:2008 | 06 | 2008 | INSULATE BARE EQUIPMENT | $150 | $809 | Not Implemented |
LL0294 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $4,740 | $2,539 | Not Implemented |
LL0294 # 06 Y:2008 | 06 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,006 | $1,880 | Not Implemented |
LL0294 # 07 Y:2008 | 07 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,841 | $210 | Not Implemented |
LL0294 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $645 | $90 | Implemented |
LL0294 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $527 | $350 | Not Implemented |
LL0294 # 04 Y:2008 | 04 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,897 | $1,210 | Implemented |
LL0294 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,541 | $10,640 | Not Implemented |
LL0294 # 02 Y:2008 | 02 | 2008 | OPTIMIZE PLANT POWER FACTOR | $16,326 | $5,201 | Not Implemented |
LL0294 # 01 Y:2008 | 01 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $31,560 | $45,800 | Not Implemented |