Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 39 | Miscellaneous Manufacturing Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1709 # 13 Y:2017 | 13 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $941 | $1,492 | Not Implemented |
UK1709 # 12 Y:2017 | 12 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,293 | $1,481 | Not Implemented |
UK1709 # 11 Y:2017 | 11 | 2017 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,368 | $113 | Not Implemented |
UK1709 # 10 Y:2017 | 10 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,596 | $2,983 | Not Implemented |
UK1709 # 09 Y:2017 | 09 | 2017 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $1,400 | $2,734 | Not Implemented |
UK1709 # 08 Y:2017 | 08 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,908 | $0 | Not Implemented |
UK1709 # 07 Y:2017 | 07 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,536 | $0 | Not Implemented |
UK1709 # 06 Y:2017 | 06 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,910 | $0 | Not Implemented |
UK1709 # 05 Y:2017 | 05 | 2017 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $5,407 | $3,304 | Not Implemented |
UK1709 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,732 | $2,100 | Not Implemented |
UK1709 # 02 Y:2017 | 02 | 2017 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $1,143 | $0 | Not Implemented |
UK1709 # 03 Y:2017 | 03 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,114 | $453 | Not Implemented |
UK1709 # 04 Y:2017 | 04 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $338 | $0 | Not Implemented |
SD0555 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,771 | $1,100 | Implemented |
SD0555 # 01 Y:2017 | 01 | 2017 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $18,916 | $65,600 | Not Implemented |
SD0555 # 03 Y:2017 | 03 | 2017 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,035 | $6,550 | Not Implemented |
SD0555 # 04 Y:2017 | 04 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $489 | $600 | Implemented |
SD0555 # 05 Y:2017 | 05 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $445 | $850 | Not Implemented |
OR0690 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,285 | $2,321 | Implemented |
OR0690 # 02 Y:2017 | 02 | 2017 | USE RADIANT HEATER FOR SPOT HEATING | $1,989 | $1,874 | Not Implemented |
OR0690 # 01 Y:2017 | 01 | 2017 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,526 | $429 | Not Implemented |
SD0553 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,930 | $7,400 | Implemented |
SD0553 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,604 | $600 | Not Implemented |
SD0553 # 03 Y:2017 | 03 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,203 | $59,750 | Implemented |
SD0553 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,252 | $39,079 | Implemented |