Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
53
matching recommendationsSIC | 394 | Toys And Sporting Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0197 # 12 Y:1997 | 12 | 1997 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $58,584 | $15,000 | Not Implemented |
AS0197 # 11 Y:1997 | 11 | 1997 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $17,366 | $4,500 | Not Implemented |
AS0197 # 10 Y:1997 | 10 | 1997 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $1,093 | $779 | Not Implemented |
AS0197 # 08 Y:1997 | 08 | 1997 | INSTALL OCCUPANCY SENSORS | $5,740 | $12,300 | Not Implemented |
AS0197 # 07 Y:1997 | 07 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,006 | $180 | Implemented |
AS0197 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $779 | $1,680 | Implemented |
AS0197 # 05 Y:1997 | 05 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $319 | $0 | Implemented |
AS0197 # 04 Y:1997 | 04 | 1997 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $4,699 | $3,600 | Not Implemented |
AS0197 # 03 Y:1997 | 03 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,704 | $21,700 | Implemented |
AS0197 # 02 Y:1997 | 02 | 1997 | USE SYNTHETIC LUBRICANT | $2,789 | $1,625 | Implemented |
AS0197 # 01 Y:1997 | 01 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,219 | $0 | Not Implemented |
AS0163 # 07 Y:1995 | 07 | 1995 | INSULATE BARE EQUIPMENT | $3,121 | $3,655 | Not Implemented |
AS0163 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,110 | $9,153 | Not Implemented |
AS0163 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $1,499 | $1,135 | Not Implemented |
AS0163 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,808 | $14,235 | Not Implemented |
AS0163 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,608 | $0 | Implemented |
AS0163 # 05 Y:1995 | 05 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $595 | $500 | Implemented |
AS0163 # 06 Y:1995 | 06 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,952 | $7,500 | Not Implemented |
AS0058 # 02 Y:1992 | 02 | 1992 | USE HEAT PUMP FOR SPACE CONDITIONING | $33,994 | $182,325 | Implemented |
AS0058 # 03 Y:1992 | 03 | 1992 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $2,531 | $3,100 | Implemented |
AS0058 # 04 Y:1992 | 04 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $776 | $1,400 | Implemented |
AS0058 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,087 | $200 | Implemented |
AS0058 # 06 Y:1992 | 06 | 1992 | REDUCE VENTILATION AIR | $470 | $400 | Implemented |
AS0058 # 07 Y:1992 | 07 | 1992 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $539 | $114 | Implemented |
AS0058 # 08 Y:1992 | 08 | 1992 | INSULATE BARE EQUIPMENT | $273 | $100 | Implemented |