Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
626
matching recommendationsSIC | 394 | Toys And Sporting Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0646 # 03 Y:2011 | 03 | 2011 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $2,120 | $10,000 | Implemented |
CO0646 # 04 Y:2011 | 04 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,080 | $14,690 | Not Implemented |
CO0646 # 05 Y:2011 | 05 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,910 | $35,000 | Not Implemented |
CO0646 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,340 | $2,730 | Implemented |
CO0646 # 07 Y:2011 | 07 | 2011 | INSTALL WIND POWERED ELECTRIC GENERATOR | $270 | $5,260 | Not Implemented |
CO0646 # 08 Y:2011 | 08 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $150 | $40 | Implemented |
IA0455 # 01 Y:2010 | 01 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,148 | $1,000 | Implemented |
IA0455 # 02 Y:2010 | 02 | 2010 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,026 | $620 | Not Implemented |
IA0455 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $562 | $14 | Implemented |
IA0455 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,132 | $14 | Not Implemented |
IA0455 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,112 | $240 | Implemented |
IA0455 # 06 Y:2010 | 06 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,817 | $3,837 | Not Implemented |
IA0455 # 07 Y:2010 | 07 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $165 | $112 | Implemented |
IA0455 # 08 Y:2010 | 08 | 2010 | INSTALL OCCUPANCY SENSORS | $6,632 | $9,702 | Implemented |
IA0455 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $1,331 | $3,960 | Implemented |
IA0455 # 10 Y:2010 | 10 | 2010 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $28,440 | $1,320 | Not Implemented |
IA0455 # 11 Y:2010 | 11 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,067 | $2,556 | Not Implemented |
IA0455 # 12 Y:2010 | 12 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,138 | $4,417 | Implemented |
BD0373 # 07 Y:2010 | 07 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $2,064 | $3,000 | Not Implemented |
BD0373 # 06 Y:2010 | 06 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $40,661 | $54,000 | Not Implemented |
BD0373 # 05 Y:2010 | 05 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,349 | $2,000 | Not Implemented |
BD0373 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,113 | $800 | Not Implemented |
BD0373 # 03 Y:2010 | 03 | 2010 | USE PHOTOCELL CONTROLS | $1,390 | $3,600 | Not Implemented |
BD0373 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $2,326 | $2,100 | Not Implemented |
BD0373 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,308 | $48,175 | Not Implemented |