Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,432
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0087 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,200 | $5,400 | Implemented |
DL0087 # 09 Y:2012 | 09 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $79,600 | $29,600 | Not Implemented |
DL0087 # 10 Y:2012 | 10 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $18,230 | $71,500 | Not Implemented |
DL0087 # 11 Y:2012 | 11 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $60,100 | $101,500 | Not Implemented |
BD0411 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $5,581 | $4,200 | Not Implemented |
BD0411 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,064 | $16,570 | Not Implemented |
BD0411 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,039 | $10 | Not Implemented |
BD0411 # 04 Y:2012 | 04 | 2012 | USE POWER DURING OFF-PEAK PERIODS | $845 | $10 | Not Implemented |
BD0411 # 05 Y:2012 | 05 | 2012 | USE SYNTHETIC LUBRICANT | $541 | $350 | Not Implemented |
BD0411 # 06 Y:2012 | 06 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $487 | $650 | Not Implemented |
BD0411 # 07 Y:2012 | 07 | 2012 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $54,939 | $6,500 | Not Implemented |
BD0411 # 08 Y:2012 | 08 | 2012 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,915 | $5,500 | Not Implemented |
BD0411 # 09 Y:2012 | 09 | 2012 | AUTOMATE PAYROLL SYSTEM | $3,366 | $1,500 | Not Implemented |
MAS017 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $34,566 | $10,000 | Implemented |
MAS017 # 02 Y:2012 | 02 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $4,892 | $15,000 | Not Implemented |
MAS017 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $511 | $200 | Not Implemented |
MAS016 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,510 | $5,600 | Implemented |
MAS016 # 02 Y:2012 | 02 | 2012 | RECOVER AND REUSE COOLING WATER | $79 | $375 | Not Implemented |
MAS016 # 03 Y:2012 | 03 | 2012 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $9,910 | $0 | Implemented |
MI0201 # 01 Y:2011 | 01 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $36,428 | $124,975 | Not Implemented |
MI0201 # 02 Y:2011 | 02 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,894 | $2,000 | Implemented |
MI0201 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $18,870 | $7,920 | Implemented |
MI0201 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,184 | $41,193 | Not Implemented |
MI0201 # 05 Y:2011 | 05 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,322 | $1,275 | Not Implemented |
MI0201 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,700 | $1,210 | Not Implemented |