Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2012 |
Principal Product | Remanufactured Beverage Dispensers |
NAICS | 339999 - All Other Miscellaneous Manufacturing |
SIC | 3999 - Manufacturing Industries, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 128 |
Plant Area (Sq.Ft.) | 170,000 |
Annual Production | 32,000 Pieces |
Production Hrs. Annual | 2,470 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $38,899 | 549,498 | kWh | $0.07 |
Electricity Demand | $12,775 | 1,944 | kW-months/year | $6.57 |
Electricity Fees | $2,729 | - | $ | - |
Natural Gas | $36,944 | 4,341 | MMBtu | $8.51 |
LPG | $17,363 | 380 | MMBtu | $45.67 |
TOTAL ENERGY COSTS | $108,710 | |||
RECOMMENDED SAVINGS* | $74,777 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Personnel Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,581 Cost: $4,200 |
$3,697 | 55,839 | $1,884 | 287 | - | - | - | - |
$3,697 55,839 kWh |
$1,884 287 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,064 Cost: $16,570 |
$2,743 | 41,463 | $1,321 | 201 | - | - | - | - |
$2,743 41,463 kWh |
$1,321 201 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,039 Cost: $10 |
$701 | 10,595 | $338 | 52 | - | - | - | - |
$701 10,595 kWh |
$338 52 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $845 Cost: $10 |
- | - | $845 | 129 | - | - | - | - |
- - kWh |
$845 129 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $541 Cost: $350 |
$366 | 5,528 | $175 | 27 | - | - | - | - |
$366 5,528 kWh |
$175 27 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $487 Cost: $650 |
$329 | 4,965 | $158 | 24 | - | - | - | - |
$329 4,965 kWh |
$158 24 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $54,939 Cost: $6,500 |
$(-211) | (-3,193) | - | - | $(-1,650) | - | $56,800 | - |
$(-211) (-3,193) kWh |
- - kW-months/year |
$(-1,650) - $ |
$56,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $3,915 Cost: $5,500 |
- | - | - | - | - | - | $3,915 | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,915 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.447 AUTOMATE PAYROLL SYSTEM |
Savings: $3,366 Cost: $1,500 |
- | - | - | - | $3,366 | - | - | - |
- - kWh |
- - kW-months/year |
$3,366 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $74,777 Cost: $35,290 |
$7,625 | 115,197 | $4,721 | 719 | $1,716 | - | $60,715 | - | $7,625 115,197 kWh |
$4,721 719 kW-months/year |
$1,716 - $ |
$60,715 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Personnel Changes | By-product Production |