Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
67
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0448 # 03 Y:1992 | 03 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,031 | $2,450 | Not Implemented |
TN0448 # 02 Y:1992 | 02 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,674 | $360 | Not Implemented |
TN0448 # 01 Y:1992 | 01 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,065 | $1,820 | Not Implemented |
TN0436 # 01 Y:1991 | 01 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $26,217 | $1,204 | Implemented |
TN0436 # 02 Y:1991 | 02 | 1991 | REPAIR AND ELIMINATE STEAM LEAKS | $9,331 | $500 | Implemented |
TN0436 # 03 Y:1991 | 03 | 1991 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,936 | $12,057 | Implemented |
TN0436 # 04 Y:1991 | 04 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,440 | $0 | Implemented |
TN0436 # 05 Y:1991 | 05 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $3,626 | $0 | Implemented |
TN0436 # 06 Y:1991 | 06 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,646 | $19,100 | Implemented |
TN0436 # 07 Y:1991 | 07 | 1991 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $487 | $0 | Implemented |
TN0436 # 08 Y:1991 | 08 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $162 | $392 | Implemented |
TN0410 # 04 Y:1990 | 04 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $11,650 | $7,440 | Not Implemented |
TN0410 # 01 Y:1990 | 01 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $25,287 | $29,907 | Implemented |
TN0410 # 02 Y:1990 | 02 | 1990 | INSTALL SET-BACK TIMERS | $11,948 | $0 | Implemented |
TN0410 # 10 Y:1990 | 10 | 1990 | ADJUST VENTS TO MINIMIZE ENERGY USE | $975 | $1,545 | Not Implemented |
TN0410 # 09 Y:1990 | 09 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,602 | $0 | Implemented |
TN0410 # 08 Y:1990 | 08 | 1990 | ADJUST VENTS TO MINIMIZE ENERGY USE | $2,515 | $3,600 | Implemented |
TN0410 # 07 Y:1990 | 07 | 1990 | IMPROVE LUBRICATION PRACTICES | $3,261 | $0 | Not Implemented |
TN0410 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $9,891 | $7,200 | Not Implemented |
TN0410 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,844 | $930 | Implemented |
TN0410 # 03 Y:1990 | 03 | 1990 | OPTIMIZE PLANT POWER FACTOR | $13,343 | $44,500 | Implemented |
TN0345 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,491 | $0 | Implemented |
TN0345 # 06 Y:1988 | 06 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $513 | $270 | Not Implemented |
TN0345 # 04 Y:1988 | 04 | 1988 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $770 | $0 | Implemented |
TN0345 # 03 Y:1988 | 03 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $135 | $5,000 | Not Implemented |