Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0501 # 04 Y:2020 | 04 | 2020 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $556 | $999 | Not Implemented |
SU0501 # 03 Y:2020 | 03 | 2020 | ELIMINATE/REDUCE AN OPERATION | $2,583 | $2,772 | Not Implemented |
SU0501 # 02 Y:2020 | 02 | 2020 | DISCONNECT BALLASTS | $919 | $180 | Not Implemented |
SU0501 # 01 Y:2020 | 01 | 2020 | ELIMINATE/REDUCE AN OPERATION | $557 | $20 | Not Implemented |
SU0501 # 05 Y:2020 | 05 | 2020 | REDUCE VENTILATION AIR | $273 | $882 | Not Implemented |
SU0193 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $489 | $304 | Implemented |
SU0193 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $942 | $363 | Implemented |
SU0193 # 09 Y:2004 | 09 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,340 | $10,000 | Not Implemented |
SU0193 # 08 Y:2004 | 08 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,989 | $10,421 | Implemented |
SU0193 # 04 Y:2004 | 04 | 2004 | USE SYNTHETIC LUBRICANT | $1,343 | $200 | Implemented |
SU0193 # 03 Y:2004 | 03 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,396 | $0 | Implemented |
SU0193 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,779 | $0 | Implemented |
SU0193 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,858 | $0 | Implemented |
SU0193 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,158 | $2,415 | Not Implemented |
SU0105 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $264 | $90 | Implemented |
SU0105 # 06 Y:2001 | 06 | 2001 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $34,064 | $380,000 | Not Implemented |
SU0105 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $258 | $0 | Implemented |
SU0105 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $993 | $123 | Implemented |
SU0105 # 02 Y:2001 | 02 | 2001 | INSULATE BARE EQUIPMENT | $1,285 | $38 | Not Implemented |
SU0105 # 01 Y:2001 | 01 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,365 | $0 | Implemented |
SU0102 # 02 Y:2001 | 02 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $4,867 | $234 | Implemented |
SU0102 # 04 Y:2001 | 04 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $231 | $250 | Not Implemented |
SU0102 # 06 Y:2001 | 06 | 2001 | INSTALL OCCUPANCY SENSORS | $189 | $244 | Not Implemented |
SU0102 # 03 Y:2001 | 03 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $758 | $1,323 | Implemented |
SU0102 # 05 Y:2001 | 05 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $30,000 | $34,762 | Not Implemented |