Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
350
matching recommendationsSIC | 3993 | Signs And Advertising Specialities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0363 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,259 | $122,100 | Implemented |
WV0363 # 04 Y:2007 | 04 | 2007 | COMBINE UTILITY METERS | $11,248 | $12,500 | Not Implemented |
WV0363 # 05 Y:2007 | 05 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,928 | $511 | Implemented |
WV0363 # 06 Y:2007 | 06 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,228 | $9,945 | Implemented |
WV0363 # 07 Y:2007 | 07 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $7,036 | $984 | Not Implemented |
WV0363 # 08 Y:2007 | 08 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,820 | $183 | Implemented |
WV0363 # 09 Y:2007 | 09 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $3,839 | $1,105 | Not Implemented |
UA0006 # 01 Y:2007 | 01 | 2007 | USE PHOTOCELL CONTROLS | $112 | $36 | Not Implemented |
UA0006 # 02 Y:2007 | 02 | 2007 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,561 | $1,023 | Not Implemented |
UA0006 # 03 Y:2007 | 03 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $40 | $10 | Not Implemented |
UA0006 # 04 Y:2007 | 04 | 2007 | DISCONNECT BALLASTS | $497 | $216 | Implemented |
UA0006 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $358 | $276 | Implemented |
UA0006 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $120 | $0 | Implemented |
BD0306 # 01 Y:2006 | 01 | 2006 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $26,169 | $32,500 | Implemented |
BD0306 # 02 Y:2006 | 02 | 2006 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $6,891 | $4,000 | Implemented |
BD0306 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $15,291 | $1,368 | Implemented |
BD0306 # 04 Y:2006 | 04 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $13,127 | $27,572 | Implemented |
BD0306 # 05 Y:2006 | 05 | 2006 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $424 | $237 | Implemented |
BD0306 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $2,979 | $1,350 | Implemented |
BD0306 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,520 | $4,820 | Not Implemented |
BD0306 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,310 | $900 | Implemented |
UU0073 # 01 Y:2004 | 01 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,250 | $8,000 | Not Implemented |
UU0073 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,080 | $860 | Not Implemented |
UU0073 # 03 Y:2004 | 03 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $990 | $6,000 | Not Implemented |
UU0073 # 04 Y:2004 | 04 | 2004 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $2,434 | $0 | Not Implemented |