Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsSIC | 3999 | Manufacturing Industries, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0112 # 07 Y:1998 | 07 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $10,920 | $550 | Not Implemented |
OD0112 # 06 Y:1998 | 06 | 1998 | MINIMIZE WATER USAGE | $105 | $0 | Not Implemented |
OD0112 # 05 Y:1998 | 05 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,125 | $8,000 | Implemented |
OD0112 # 04 Y:1998 | 04 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $253 | $50 | Implemented |
OD0112 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $642 | $800 | Implemented |
OD0112 # 02 Y:1998 | 02 | 1998 | REPAIR OR REPLACE STEAM TRAPS | $4,912 | $990 | Implemented |
OD0112 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,091 | $8,577 | Implemented |
OD0079 # 10 Y:1997 | 10 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $367 | $132 | Not Implemented |
OD0079 # 12 Y:1997 | 12 | 1997 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $240,000 | $96,000 | Not Implemented |
OD0079 # 11 Y:1997 | 11 | 1997 | TREAT AND REUSE RINSE WATERS | $28,199 | $7,524 | Not Implemented |
OD0079 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $635 | $2,246 | Not Implemented |
OD0079 # 09 Y:1997 | 09 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $11,623 | $5,412 | Not Implemented |
OD0079 # 08 Y:1997 | 08 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,369 | $5,800 | Not Implemented |
OD0079 # 07 Y:1997 | 07 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $676 | $1,495 | Not Implemented |
OD0079 # 06 Y:1997 | 06 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $14,664 | $0 | Not Implemented |
OD0079 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,186 | $600 | Not Implemented |
OD0079 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,130 | $1,301 | Not Implemented |
OD0079 # 03 Y:1997 | 03 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,271 | $2,578 | Not Implemented |
OD0079 # 02 Y:1997 | 02 | 1997 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,524 | $0 | Not Implemented |