Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3999 | Manufacturing Industries, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0793 # 02 Y:2010 | 02 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $150,096 | $1,969,500 | Not Implemented |
OK0793 # 01 Y:2010 | 01 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $88,705 | $104,400 | Implemented |
OK0793 # 13 Y:2010 | 13 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $27,218 | $30,300 | Implemented |
OK0793 # 12 Y:2010 | 12 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,071 | $995 | Implemented |
OK0793 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $21,881 | $4,522 | Not Implemented |
OK0793 # 10 Y:2010 | 10 | 2010 | INSULATE BARE EQUIPMENT | $67,527 | $42,259 | Not Implemented |
OK0793 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,136 | $21,130 | Not Implemented |
OK0793 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,971 | $111,113 | Not Implemented |
OK0793 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,411 | $69,755 | Not Implemented |
OK0793 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $8,717 | $17,813 | Implemented |
OK0793 # 05 Y:2010 | 05 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $104,850 | $134,480 | Not Implemented |
OK0793 # 04 Y:2010 | 04 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $217,752 | $100,000 | Not Implemented |
OK0793 # 03 Y:2010 | 03 | 2010 | INSTALL REPLACEMENT DOORS | $1,246 | $33,150 | Not Implemented |
UM0367 # 14 Y:2010 | 14 | 2010 | INSTALL STORM WINDOWS AND DOORS | $171 | $1,400 | Implemented |
UM0367 # 13 Y:2010 | 13 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $277 | $329 | Implemented |
UM0367 # 12 Y:2010 | 12 | 2010 | INSULATE BARE EQUIPMENT | $573 | $3,568 | Not Implemented |
UM0367 # 11 Y:2010 | 11 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,186 | $7,500 | Implemented |
UM0367 # 10 Y:2010 | 10 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $4,999 | $8,600 | Not Implemented |
UM0367 # 09 Y:2010 | 09 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,537 | $10,500 | Not Implemented |
UM0367 # 08 Y:2010 | 08 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,939 | $500 | Implemented |
UM0367 # 07 Y:2010 | 07 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $17,317 | $9,800 | Implemented |
UM0367 # 06 Y:2010 | 06 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $27,997 | $68,395 | Implemented |
UM0367 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,497 | $200 | Not Implemented |
UM0367 # 04 Y:2010 | 04 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,913 | $2,000 | Implemented |
UM0367 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,249 | $1,158 | Not Implemented |