Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

70

matching recommendations
Reset
SIC 47 Transportation Services
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0450 # 08 Y:2014 08 2014 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $461 $320 Not Implemented
BD0450 # 09 Y:2014 09 2014 INSTALL OCCUPANCY SENSORS $406 $750 Not Implemented
BD0450 # 10 Y:2014 10 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $322 $143 Not Implemented
SD0429 # 01 Y:2010 01 2010 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,033 $100 Not Implemented
SD0429 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $340 $100 Implemented
SD0429 # 03 Y:2010 03 2010 INSTALL OCCUPANCY SENSORS $1,115 $587 Not Implemented
SD0429 # 04 Y:2010 04 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,424 $2,000 Not Implemented
SD0429 # 05 Y:2010 05 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $945 $2,000 Not Implemented
SD0429 # 06 Y:2010 06 2010 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $194 $500 Not Implemented
SU0157 # 10 Y:2003 10 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $803 $406 Not Implemented
SU0157 # 11 Y:2003 11 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $376 $558 Implemented
SU0157 # 09 Y:2003 09 2003 INSTALL OCCUPANCY SENSORS $849 $640 Not Implemented
SU0157 # 08 Y:2003 08 2003 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $858 $0 Not Implemented
SU0157 # 07 Y:2003 07 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,147 $0 Implemented
SU0157 # 06 Y:2003 06 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,020 $7,486 Not Implemented
SU0157 # 05 Y:2003 05 2003 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,647 $8,000 Not Implemented
SU0157 # 04 Y:2003 04 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $1,835 $0 Implemented
SU0157 # 03 Y:2003 03 2003 RECOVER WASTE HEAT FROM EQUIPMENT $7,728 $2,468 Not Implemented
SU0157 # 02 Y:2003 02 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,969 $11,310 Not Implemented
SU0157 # 01 Y:2003 01 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $45,993 $0 Not Implemented