Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
94
matching recommendationsSIC | 4941 | Water Supply |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0637 # 04 Y:2019 | 04 | 2019 | OPTIMIZE PLANT POWER FACTOR | $1,499 | $12,000 | Not Implemented |
NC0637 # 03 Y:2019 | 03 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $20,241 | $210,000 | Not Implemented |
NC0637 # 02 Y:2019 | 02 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,505 | $30,000 | Not Implemented |
NC0637 # 01 Y:2019 | 01 | 2019 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $23,778 | $10,000 | Not Implemented |
UA0218 # 04 Y:2019 | 04 | 2019 | OPTIMIZE PLANT POWER FACTOR | $7,816 | $6,955 | Not Implemented |
UA0218 # 03 Y:2019 | 03 | 2019 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $27,441 | $2,000 | Not Implemented |
UA0218 # 02 Y:2019 | 02 | 2019 | INSTALL OCCUPANCY SENSORS | $1,874 | $198 | Implemented |
UA0218 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,378 | $6,360 | Implemented |
TR0019 # 01 Y:2019 | 01 | 2019 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $41,476 | $21,000 | Not Implemented |
TR0019 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $637 | $2,470 | Implemented |
TR0019 # 03 Y:2019 | 03 | 2019 | INSTALL WIND POWERED ELECTRIC GENERATOR | $135,960 | $1,346,000 | Not Implemented |
NC0640 # 02 Y:2019 | 02 | 2019 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $30,092 | $500 | Implemented |
NC0640 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $264 | $1,283 | Not Implemented |
NC0640 # 03 Y:2019 | 03 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $19,071 | $157,500 | Not Implemented |
NC0640 # 01 Y:2019 | 01 | 2019 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,832 | $700 | Not Implemented |
TR0016 # 08 Y:2019 | 08 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $104,866 | $89,113 | Not Implemented |
TR0016 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,354 | $4,519 | Implemented |
TR0016 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,876 | $1,778 | Implemented |
TR0016 # 03 Y:2019 | 03 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,445 | $0 | Implemented |
WV0586 # 05 Y:2019 | 05 | 2019 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,701 | $1,000 | Implemented |
WV0586 # 03 Y:2019 | 03 | 2019 | DEVELOP A REPAIR/REPLACE POLICY | $3,336 | $894 | Implemented |
WV0586 # 04 Y:2019 | 04 | 2019 | LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT | $3,276 | $11,875 | Not Implemented |
WV0586 # 02 Y:2019 | 02 | 2019 | LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT | $31,539 | $1,630 | Implemented |
WV0586 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,909 | $2,793 | Implemented |
WV0586 # 07 Y:2019 | 07 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,900 | $0 | Not Implemented |