Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,634
matching recommendationsSIC | 4952 | Sewerage Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0566 # 04 Y:2021 | 04 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,332 | $0 | Implemented |
UF0566 # 05 Y:2021 | 05 | 2021 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $450,043 | $53,000 | Not Implemented |
UF0566 # 06 Y:2021 | 06 | 2021 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,159 | $4,000 | Not Implemented |
UF0566 # 07 Y:2021 | 07 | 2021 | MINIMIZE WATER USAGE | $1,899 | $0 | Implemented |
UF0566 # 08 Y:2021 | 08 | 2021 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $1,187 | $0 | Implemented |
UF0565 # 01 Y:2021 | 01 | 2021 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $124,268 | $90,000 | Not Implemented |
UF0565 # 02 Y:2021 | 02 | 2021 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $120,536 | $84,600 | Not Implemented |
UF0565 # 03 Y:2021 | 03 | 2021 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $52,797 | $9,223 | Not Implemented |
UF0565 # 04 Y:2021 | 04 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,569 | $48,945 | Implemented |
UF0565 # 05 Y:2021 | 05 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $29,289 | $0 | Not Implemented |
UF0565 # 06 Y:2021 | 06 | 2021 | INSTALL OCCUPANCY SENSORS | $2,587 | $12,332 | Implemented |
UF0565 # 07 Y:2021 | 07 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,574 | $0 | Implemented |
UF0565 # 08 Y:2021 | 08 | 2021 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $381,639 | $1,857,208 | Not Implemented |
UF0565 # 09 Y:2021 | 09 | 2021 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $1,621 | $0 | Implemented |
UK2104 # 01 Y:2021 | 01 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,514 | $444 | n/a |
UK2104 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,021 | $2,633 | n/a |
UK2104 # 03 Y:2021 | 03 | 2021 | INSTALL OCCUPANCY SENSORS | $231 | $650 | n/a |
UK2104 # 04 Y:2021 | 04 | 2021 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $85 | $285 | n/a |
UK2104 # 05 Y:2021 | 05 | 2021 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $26,160 | $9,000 | n/a |
UK2104 # 06 Y:2021 | 06 | 2021 | REDESIGN PROCESS | $16,187 | $25,000 | n/a |
UK2104 # 07 Y:2021 | 07 | 2021 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,415 | $13,780 | n/a |
UK2104 # 08 Y:2021 | 08 | 2021 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $21,003 | $0 | n/a |
UK2104 # 09 Y:2021 | 09 | 2021 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $13,774 | $4,000 | n/a |
UK2104 # 10 Y:2021 | 10 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $356 | $78 | n/a |
UF0564 # 01 Y:2021 | 01 | 2021 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $235,547 | $75,000 | Not Implemented |