Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 516 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0585 # 03 Y:2025 | 03 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,395 | $660 | n/a |
LE0585 # 01 Y:2025 | 01 | 2025 | INSTALL TIMERS AND/OR THERMOSTATS | $27,784 | $0 | n/a |
LE0585 # 05 Y:2025 | 05 | 2025 | USE SOLAR HEAT TO HEAT WATER | $132,239 | $658,000 | n/a |
LE0585 # 02 Y:2025 | 02 | 2025 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,317 | $2,200 | n/a |
LE0585 # 04 Y:2025 | 04 | 2025 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,641 | $25,639 | n/a |
LE0566 # 04 Y:2024 | 04 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,023 | $1,320 | n/a |
LE0566 # 08 Y:2024 | 08 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,054 | $17,765 | n/a |
LE0566 # 06 Y:2024 | 06 | 2024 | INSTALL OCCUPANCY SENSORS | $403 | $210 | n/a |
LE0566 # 02 Y:2024 | 02 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,026 | $100 | n/a |
LE0566 # 05 Y:2024 | 05 | 2024 | INSTALL TIMERS AND/OR THERMOSTATS | $1,530 | $640 | n/a |
LE0566 # 07 Y:2024 | 07 | 2024 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,444 | $1,000 | n/a |
LE0566 # 03 Y:2024 | 03 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,974 | $1,450 | n/a |
LE0566 # 01 Y:2024 | 01 | 2024 | UPGRADE CONTROLS ON COMPRESSORS | $6,466 | $600 | n/a |
DL0105 # 09 Y:2013 | 09 | 2013 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,350 | $3,200 | Not Implemented |
DL0105 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,000 | $80 | Implemented |
DL0105 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,200 | $2,300 | Not Implemented |
DL0105 # 06 Y:2013 | 06 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,400 | $590 | Not Implemented |
DL0105 # 05 Y:2013 | 05 | 2013 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $16,300 | $500 | Not Implemented |
DL0105 # 04 Y:2013 | 04 | 2013 | ADD AREA LIGHTING SWITCHES | $18,950 | $1,400 | Implemented |
DL0105 # 03 Y:2013 | 03 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $20,300 | $8,000 | Not Implemented |
DL0105 # 02 Y:2013 | 02 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $54,800 | $200 | Not Implemented |
DL0105 # 01 Y:2013 | 01 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $76,200 | $13,500 | Implemented |
DL0105 # 10 Y:2013 | 10 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $154,000 | $1,000,000 | Implemented |
DL0105 # 11 Y:2013 | 11 | 2013 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $82,900 | $420,000 | Implemented |
UF0423 # 12 Y:2009 | 12 | 2009 | INSULATE BARE EQUIPMENT | $159,410 | $5,591 | Not Implemented |