Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
53
matching recommendationsSIC | 7999 | Amusement And Recreation, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1136 # 01 Y:2025 | 01 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,211 | $2,580 | n/a |
OK1136 # 02 Y:2025 | 02 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $7,297 | $87,210 | n/a |
OK1136 # 04 Y:2025 | 04 | 2025 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,441 | $0 | n/a |
OK1136 # 03 Y:2025 | 03 | 2025 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,165 | $1,424 | n/a |
MZ1008 # 03 Y:2024 | 03 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,312 | $1,550 | n/a |
MZ1008 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO HEAT WATER | $343 | $3,500 | n/a |
MZ1008 # 01 Y:2024 | 01 | 2024 | INSTALL OCCUPANCY SENSORS | $1,612 | $2,450 | n/a |
LS0124 # 01 Y:2024 | 01 | 2024 | LEVEL TWO – INSTALL CONTROL SYSTEM USING IIOT DEVICES WITH COMMUNICATION CAPABILITIES TO STORE DATA TO THE CLOUD | $12,447 | $6,930 | Not Implemented |
LS0124 # 02 Y:2024 | 02 | 2024 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $24,894 | $59,475 | Not Implemented |
LS0124 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,107 | $3,300 | Implemented |
OK1101 # 03 Y:2023 | 03 | 2023 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,746 | $1,530 | Not Implemented |
OK1101 # 02 Y:2023 | 02 | 2023 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,367 | $34,835 | Not Implemented |
OK1101 # 04 Y:2023 | 04 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,284 | $18,000 | Not Implemented |
OK1101 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,452 | $2,800 | Implemented |
OK1100 # 01 Y:2023 | 01 | 2023 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,078 | $1,122 | Not Implemented |
OK1100 # 02 Y:2023 | 02 | 2023 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $392 | $1,586 | Not Implemented |
OK1100 # 03 Y:2023 | 03 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,157 | $3,000 | Not Implemented |
OK1100 # 04 Y:2023 | 04 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $19,727 | $187,200 | Not Implemented |
LS1123 # 01 Y:2023 | 01 | 2023 | INSTALL TIMERS AND/OR THERMOSTATS | $2,082 | $150 | Implemented |
LS1123 # 02 Y:2023 | 02 | 2023 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,809 | $300 | Implemented |
LS1123 # 03 Y:2023 | 03 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,349 | $1,730 | Implemented |
LS1123 # 04 Y:2023 | 04 | 2023 | INSTALL OCCUPANCY SENSORS | $79 | $75 | Implemented |
LS1123 # 05 Y:2023 | 05 | 2023 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,321 | $2,881 | Implemented |
LS0223 # 03 Y:2023 | 03 | 2023 | INSTALL OCCUPANCY SENSORS | $39 | $50 | Implemented |
LS0223 # 02 Y:2023 | 02 | 2023 | INSTALL TIMERS AND/OR THERMOSTATS | $160 | $50 | Implemented |