Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
62
matching recommendationsSIC | 80 | Health Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MUCM25 # 01 Y:2024 | 01 | 2024 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $182 | $0 | n/a |
MUCM25 # 02 Y:2024 | 02 | 2024 | USE PHOTOCELL CONTROLS | $92 | $401 | n/a |
MUCM25 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $350 | $1,478 | n/a |
MUCM25 # 04 Y:2024 | 04 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43 | $0 | n/a |
MUCM25 # 05 Y:2024 | 05 | 2024 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $359 | $0 | n/a |
MUCM25 # 06 Y:2024 | 06 | 2024 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $193 | $307 | n/a |
MUCM25 # 07 Y:2024 | 07 | 2024 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,443 | $13,685 | n/a |
MUCM25 # 08 Y:2024 | 08 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,620 | $12,320 | n/a |
AS0592 # 06 Y:2024 | 06 | 2024 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $291 | $140 | n/a |
AS0592 # 02 Y:2024 | 02 | 2024 | REPLACE BOILER | $56,229 | $300,000 | n/a |
AS0592 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $218,122 | $1,758,568 | n/a |
AS0592 # 03 Y:2024 | 03 | 2024 | INSULATE BARE EQUIPMENT | $50,126 | $154,154 | n/a |
AS0592 # 04 Y:2024 | 04 | 2024 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $11,158 | $14,100 | n/a |
AS0592 # 05 Y:2024 | 05 | 2024 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,756 | $1,363 | n/a |
NL0100 # 02 Y:2024 | 02 | 2024 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $10,015 | $2,350 | n/a |
NL0100 # 05 Y:2024 | 05 | 2024 | INSTALL OCCUPANCY SENSORS | $385 | $2,041 | n/a |
NL0100 # 03 Y:2024 | 03 | 2024 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $2,322 | $16,000 | n/a |
NL0100 # 04 Y:2024 | 04 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $516 | $600 | n/a |
NL0100 # 01 Y:2024 | 01 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,116 | $24,513 | n/a |
NL0100 # 06 Y:2024 | 06 | 2024 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $118 | $227 | n/a |
NL0098 # 01 Y:2024 | 01 | 2024 | REPLACE BOILER | $6,690 | $32,200 | n/a |
NL0098 # 03 Y:2024 | 03 | 2024 | RECOVER AND REUSE WASTE MATERIAL | $820 | $6,490 | n/a |
NL0098 # 02 Y:2024 | 02 | 2024 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $4,787 | $10,040 | n/a |
OK1114 # 07 Y:2024 | 07 | 2024 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $609 | $17,437 | Not Implemented |
LS0624 # 04 Y:2024 | 04 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $47,604 | $514,800 | Implemented |