Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsSIC | 8062 | General Medical & Surgical Hospitals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0175 # 03 Y:2017 | 03 | 2017 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $84,055 | $4,400 | Not Implemented |
DL0175 # 04 Y:2017 | 04 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,553 | $233,080 | Not Implemented |
UA0166 # 05 Y:2016 | 05 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,707 | $120 | Implemented |
UA0166 # 01 Y:2016 | 01 | 2016 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $93,758 | $199,325 | Not Implemented |
UA0166 # 02 Y:2016 | 02 | 2016 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $25,491 | $80 | Implemented |
UA0166 # 03 Y:2016 | 03 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $26,248 | $80 | Implemented |
UA0166 # 04 Y:2016 | 04 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $14,642 | $59,120 | Not Implemented |
UA0166 # 06 Y:2016 | 06 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $617 | $200 | Implemented |
UA0166 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,666 | $38,071 | Implemented |
UA0166 # 08 Y:2016 | 08 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,753 | $1,050 | Implemented |
IA0545 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,509 | $115,341 | Implemented |
IA0545 # 01 Y:2015 | 01 | 2015 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $37,834 | $27,000 | Implemented |
IA0545 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $9,979 | $4,778 | Not Implemented |
IA0545 # 04 Y:2015 | 04 | 2015 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $5,172 | $620 | Implemented |
IA0545 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,267 | $4,620 | Implemented |
IA0545 # 06 Y:2015 | 06 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $231 | $292 | Implemented |
OK0869 # 06 Y:2013 | 06 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $4,056 | $2,140 | Implemented |
OK0869 # 02 Y:2013 | 02 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,981 | $12,378 | Not Implemented |
OK0869 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $13,630 | $23,667 | Not Implemented |
OK0869 # 07 Y:2013 | 07 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,267 | $20,900 | Not Implemented |
OK0869 # 08 Y:2013 | 08 | 2013 | INSTALL SET-BACK TIMERS | $2,563 | $0 | Not Implemented |
OK0869 # 09 Y:2013 | 09 | 2013 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $38,010 | $23,834 | Implemented |
OK0869 # 10 Y:2013 | 10 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,424 | $21,368 | Not Implemented |
OK0869 # 11 Y:2013 | 11 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $22,243 | $0 | Not Implemented |
OK0869 # 12 Y:2013 | 12 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,035 | $5,256 | Not Implemented |