Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
453
matching recommendationsSIC | 82 | Educational Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0895 # 03 Y:2024 | 03 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $11,762 | $218,737 | n/a |
OK1102 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,376 | $11,510 | Not Implemented |
OK1102 # 02 Y:2023 | 02 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $3,697 | $46,170 | Not Implemented |
OK1102 # 03 Y:2023 | 03 | 2023 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $417 | $470 | Not Implemented |
ORC011 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,565 | $11,700 | n/a |
ORC011 # 02 Y:2023 | 02 | 2023 | INSTALL OCCUPANCY SENSORS | $494 | $2,500 | n/a |
ORC011 # 03 Y:2023 | 03 | 2023 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $6,882 | $0 | n/a |
ORC011 # 04 Y:2023 | 04 | 2023 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $117 | $500 | n/a |
LS1823 # 01 Y:2023 | 01 | 2023 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $8,335 | $0 | Implemented |
LS1823 # 02 Y:2023 | 02 | 2023 | INSTALL TIMERS AND/OR THERMOSTATS | $19,295 | $900 | Implemented |
LS1823 # 03 Y:2023 | 03 | 2023 | INSTALL OCCUPANCY SENSORS | $669 | $750 | Implemented |
IP7004 # 01 Y:2023 | 01 | 2023 | INSTALL OCCUPANCY SENSORS | $258 | $393 | Not Implemented |
IP7004 # 02 Y:2023 | 02 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $44,397 | $145,038 | Not Implemented |
IP7004 # 03 Y:2023 | 03 | 2023 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,102 | $6,849 | Not Implemented |
LS1723 # 01 Y:2023 | 01 | 2023 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $12,310 | $0 | Implemented |
LS1723 # 02 Y:2023 | 02 | 2023 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,341 | $0 | Implemented |
LS1723 # 03 Y:2023 | 03 | 2023 | TURN OFF EQUIPMENT WHEN NOT IN USE | $251 | $0 | Implemented |
LS1723 # 04 Y:2023 | 04 | 2023 | INSTALL OCCUPANCY SENSORS | $817 | $350 | Not Implemented |
LS1723 # 05 Y:2023 | 05 | 2023 | REDUCE HEAT GAIN BY WINDOW TINTING | $2,045 | $2,688 | Implemented |
LS1723 # 06 Y:2023 | 06 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,787 | $15,377 | Implemented |
LS1723 # 07 Y:2023 | 07 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $43,453 | $429,000 | Not Implemented |
ORC010 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,713 | $12,000 | n/a |
ORC010 # 02 Y:2023 | 02 | 2023 | INSTALL OCCUPANCY SENSORS | $1,211 | $2,500 | n/a |
ORC010 # 03 Y:2023 | 03 | 2023 | REPLACE BOILER | $3,391 | $30,000 | n/a |
ORC010 # 04 Y:2023 | 04 | 2023 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $8,755 | $1,000 | n/a |