Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

67,034

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0046 # 01 Y:1989 01 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,516 $0 Implemented
OR0046 # 02 Y:1989 02 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,907 $0 Implemented
OR0046 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $106 $100 Implemented
OR0046 # 05 Y:1989 05 1989 OPTIMIZE PLANT POWER FACTOR $4,640 $4,500 Implemented
OR0046 # 06 Y:1989 06 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,573 $42,000 Implemented
LT0136 # 03 Y:1988 03 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $689 $1,755 Implemented
LT0136 # 04 Y:1988 04 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,235 $246 Implemented
LT0136 # 05 Y:1988 05 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $160 $0 Implemented
LT0137 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,880 $0 Implemented
LT0138 # 02 Y:1988 02 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $320 $0 Implemented
LT0138 # 04 Y:1988 04 1988 INSTALL SET-BACK TIMERS $150 $206 Implemented
LT0139 # 05 Y:1988 05 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $213 $208 Implemented
LT0140 # 01 Y:1988 01 1988 INSTALL TIMERS AND/OR THERMOSTATS $4,045 $1,350 Implemented
LT0140 # 03 Y:1988 03 1988 INSULATE BARE EQUIPMENT $945 $680 Implemented
LT0140 # 05 Y:1988 05 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $322 $0 Implemented
MA0138 # 01 Y:1988 01 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $201 $150 Implemented
MA0138 # 02 Y:1988 02 1988 INSTALL TIMERS AND/OR THERMOSTATS $13,920 $448 Implemented
MA0138 # 04 Y:1988 04 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $229 $100 Implemented
MA0138 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,901 $458 Implemented
MA0138 # 07 Y:1988 07 1988 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,812 $520 Implemented
MA0138 # 08 Y:1988 08 1988 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $1,461 $3,000 Implemented
MA0138 # 09 Y:1988 09 1988 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $2,806 $10,500 Implemented
MA0139 # 01 Y:1988 01 1988 INSTALL TIMERS AND/OR THERMOSTATS $6,928 $2,859 Implemented
MA0139 # 02 Y:1988 02 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,534 $85,000 Implemented
MA0139 # 03 Y:1988 03 1988 OPTIMIZE PLANT POWER FACTOR $19,447 $9,000 Implemented