Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
350
matching recommendationsARC | 2 | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0190 # 03 Y:1983 | 03 | 1983 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,468 | $9,000 | Implemented |
GT0191 # 06 Y:1983 | 06 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,700 | $4,500 | Implemented |
GT0195 # 01 Y:1983 | 01 | 1983 | INSULATE BARE EQUIPMENT | $1,500 | $530 | Implemented |
GT0195 # 02 Y:1983 | 02 | 1983 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $2,500 | $500 | Implemented |
GT0195 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,975 | $473 | Implemented |
GT0195 # 04 Y:1983 | 04 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,900 | $4,730 | Implemented |
TN0179 # 03 Y:1983 | 03 | 1983 | USE SOLAR HEAT TO HEAT WATER | $826 | $24,000 | Implemented |
TN0179 # 02 Y:1983 | 02 | 1983 | INSULATE BARE EQUIPMENT | $2,291 | $5,700 | Implemented |
TN0179 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $8,400 | $5,000 | Implemented |
TN0177 # 03 Y:1983 | 03 | 1983 | USE MINIMUM STEAM OPERATING PRESSURE | $2,625 | $400 | Implemented |
TN0177 # 02 Y:1983 | 02 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,540 | $400 | Implemented |
OK0110 # 07 Y:1983 | 07 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $937 | $181 | Implemented |
OK0110 # 06 Y:1983 | 06 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $343 | $80 | Implemented |
KU0106 # 08 Y:1983 | 08 | 1983 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $342 | $80 | Implemented |
KU0106 # 06 Y:1983 | 06 | 1983 | USE OPTIMUM THICKNESS INSULATION | $498 | $100 | Implemented |
KU0105 # 04 Y:1983 | 04 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,827 | $2,400 | Implemented |
KU0104 # 08 Y:1983 | 08 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $759 | $1,026 | Implemented |
KU0104 # 07 Y:1983 | 07 | 1983 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,308 | $132 | Implemented |
KU0104 # 06 Y:1983 | 06 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,791 | $5,000 | Implemented |
KU0104 # 05 Y:1983 | 05 | 1983 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $916 | $800 | Implemented |
KU0104 # 04 Y:1983 | 04 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,624 | $400 | Implemented |
KU0104 # 03 Y:1983 | 03 | 1983 | REPAIR OR REPLACE STEAM TRAPS | $2,673 | $2,000 | Implemented |
KU0104 # 02 Y:1983 | 02 | 1983 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,960 | $800 | Implemented |
KU0104 # 01 Y:1983 | 01 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,312 | $1,500 | Implemented |
KU0102 # 04 Y:1983 | 04 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $824 | $700 | Implemented |