Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,098

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0104 # 09 Y:1993 09 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $646 $301 Implemented
MO0104 # 10 Y:1993 10 1993 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $15,100 $5,240 Not Implemented
MA0289 # 01 Y:1993 01 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $8,282 $20,878 Implemented
MA0289 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,675 $4,811 Not Implemented
MA0289 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $486 $67 Implemented
MA0289 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,948 $180 Implemented
ME0115 # 01 Y:1993 01 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,628 $800 Not Implemented
ME0115 # 02 Y:1993 02 1993 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $106,916 $100,000 Not Implemented
ME0115 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $1,882 $2,500 Not Implemented
ME0115 # 04 Y:1993 04 1993 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $1,080 $3,000 Not Implemented
ME0115 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $965 $100 Implemented
ME0115 # 06 Y:1993 06 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $25,600 $2,000 Implemented
ME0115 # 07 Y:1993 07 1993 PAY UTILITY BILLS ON TIME $3,042 $0 Not Implemented
ME0116 # 01 Y:1993 01 1993 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,946 $7,000 Implemented
ME0116 # 02 Y:1993 02 1993 RECOVER WASTE HEAT FROM EQUIPMENT $270 $200 Not Implemented
ME0116 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $485 $100 Not Implemented
ME0116 # 04 Y:1993 04 1993 USE PHOTOCELL CONTROLS $2,907 $1,200 Implemented
ME0117 # 01 Y:1993 01 1993 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,377 $150 Not Implemented
ME0117 # 02 Y:1993 02 1993 OPTIMIZE PLANT POWER FACTOR $3,110 $4,500 Not Implemented
ME0117 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $228 $100 Implemented
ME0117 # 04 Y:1993 04 1993 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $6,190 $8,500 Not Implemented
ME0117 # 05 Y:1993 05 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,071 $900 Not Implemented
OR0194 # 01 Y:1993 01 1993 KEEP BOILER TUBES CLEAN $23,338 $2,500 Implemented
OR0194 # 02 Y:1993 02 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $6,588 $2,790 Not Implemented
OR0194 # 03 Y:1993 03 1993 REDUCE FLUID FLOW RATES $17,513 $22,030 Implemented