Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,843

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0099 # 01 Y:1997 01 1997 INSTALL OCCUPANCY SENSORS $1,811 $500 Not Implemented
BD0099 # 02 Y:1997 02 1997 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $1,441 $1,500 Not Implemented
BD0099 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $466 $300 Not Implemented
BD0099 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $427 $500 Not Implemented
BD0099 # 05 Y:1997 05 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $225 $340 Not Implemented
AS0215 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,408 $2,681 Implemented
AS0215 # 02 Y:1997 02 1997 INSTALL OCCUPANCY SENSORS $185 $450 Implemented
AS0215 # 03 Y:1997 03 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $371 $315 Not Implemented
AS0215 # 04 Y:1997 04 1997 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,409 $1,500 Not Implemented
AS0215 # 05 Y:1997 05 1997 INSTALL TIMERS AND/OR THERMOSTATS $564 $480 Implemented
AS0215 # 06 Y:1997 06 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $534 $30 Implemented
NV0091 # 01 Y:1997 01 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,073 $245 Implemented
NV0091 # 02 Y:1997 02 1997 INSTALL OCCUPANCY SENSORS $425 $62 Not Implemented
NV0091 # 03 Y:1997 03 1997 INSTALL TIMERS AND/OR THERMOSTATS $6,435 $380 Implemented
NV0091 # 04 Y:1997 04 1997 ADJUST BURNERS FOR EFFICIENT OPERATION $1,330 $400 Implemented
NV0091 # 05 Y:1997 05 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $262 $500 Not Implemented
MA0403 # 01 Y:1997 01 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $57,769 $221,193 Not Implemented
MA0403 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,467 $41,542 Implemented
MA0403 # 03 Y:1997 03 1997 INSULATE BARE EQUIPMENT $7,904 $4,620 Implemented
MA0403 # 04 Y:1997 04 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,578 $19,800 Not Implemented
MA0403 # 05 Y:1997 05 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,118 $5,000 Not Implemented
MA0403 # 06 Y:1997 06 1997 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $970 $900 Not Implemented
MA0403 # 07 Y:1997 07 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $278 $0 Not Implemented
SF0129 # 01 Y:1997 01 1997 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $3,157 $602 Implemented
SF0129 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $777 $2,520 Implemented