Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
147,893
matching recommendationsARC | 2 | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0283 # 08 Y:1989 | 08 | 1989 | REDESIGN PROCESS | $11,461 | $13,200 | Not Implemented |
KU0283 # 09 Y:1989 | 09 | 1989 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $241 | $0 | Implemented |
KU0283 # 10 Y:1989 | 10 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,395 | $2,300 | Not Implemented |
KU0284 # 01 Y:1989 | 01 | 1989 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $831,745 | $1,230,000 | Implemented |
KU0284 # 02 Y:1989 | 02 | 1989 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $139,391 | $226,000 | Implemented |
KU0284 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $16,143 | $5,856 | Implemented |
KU0284 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,092 | $3,080 | Implemented |
KU0284 # 05 Y:1989 | 05 | 1989 | IMPROVE LUBRICATION PRACTICES | $2,169 | $0 | Implemented |
KU0284 # 06 Y:1989 | 06 | 1989 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $618 | $0 | Implemented |
KU0284 # 07 Y:1989 | 07 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $931 | $1,018 | Implemented |
KU0284 # 08 Y:1989 | 08 | 1989 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $169 | $0 | Implemented |
TN0369 # 01 Y:1989 | 01 | 1989 | INSULATE BARE EQUIPMENT | $6,868 | $5,446 | Not Implemented |
TN0369 # 02 Y:1989 | 02 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $16,115 | $44,100 | Not Implemented |
TN0369 # 03 Y:1989 | 03 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $1,909 | $240 | Implemented |
TN0369 # 04 Y:1989 | 04 | 1989 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $2,350 | $3,325 | Implemented |
TN0369 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $11,956 | $0 | Implemented |
TN0369 # 06 Y:1989 | 06 | 1989 | INSULATE BARE EQUIPMENT | $1,483 | $300 | Not Implemented |
TN0369 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $280 | $0 | Implemented |
TN0369 # 08 Y:1989 | 08 | 1989 | CLOSE OFF UNNEEDED STEAM LINES | $845 | $0 | Implemented |
TN0369 # 09 Y:1989 | 09 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $147 | $50 | Implemented |
TN0369 # 10 Y:1989 | 10 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,943 | $450 | Implemented |
TN0372 # 01 Y:1989 | 01 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $46,225 | $71,400 | Implemented |
TN0372 # 02 Y:1989 | 02 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,688 | $1,541 | Not Implemented |
TN0372 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $10,030 | $0 | Not Implemented |
TN0372 # 04 Y:1989 | 04 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,795 | $0 | Not Implemented |