Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,386

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0078 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $810 $550 Implemented
AM0079 # 01 Y:1990 01 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,390 $2,000 Implemented
AM0079 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,990 $26,637 Implemented
AM0079 # 03 Y:1990 03 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,440 $2,000 Implemented
AM0079 # 04 Y:1990 04 1990 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,670 $4,050 Implemented
AM0079 # 05 Y:1990 05 1990 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $470 $0 Implemented
AM0079 # 06 Y:1990 06 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $340 $0 Implemented
AM0079 # 07 Y:1990 07 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $255 $90 Implemented
AM0079 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $46 $17 Implemented
KU0301 # 01 Y:1990 01 1990 INSTALL SET-BACK TIMERS $3,805 $140 Implemented
KU0301 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $467 $6,120 Implemented
KU0301 # 03 Y:1990 03 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,576 $2,878 Implemented
KU0301 # 04 Y:1990 04 1990 OPTIMIZE PLANT POWER FACTOR $15,127 $17,246 Implemented
KU0301 # 05 Y:1990 05 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,417 $0 Implemented
KU0301 # 06 Y:1990 06 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $380 $0 Implemented
KU0301 # 07 Y:1990 07 1990 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,923 $4,500 Not Implemented
KU0302 # 01 Y:1990 01 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $980 $0 Implemented
KU0302 # 02 Y:1990 02 1990 SHUT OFF PILOTS IN STANDBY EQUIPMENT $254 $0 Implemented
KU0302 # 03 Y:1990 03 1990 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $637 $500 Not Implemented
KU0302 # 04 Y:1990 04 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $265 $100 Not Implemented
KU0302 # 05 Y:1990 05 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $235 $180 Implemented
KU0302 # 06 Y:1990 06 1990 DISCONNECT BALLASTS $123 $100 Implemented
KU0302 # 07 Y:1990 07 1990 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $3,210 $0 Implemented
OK0303 # 01 Y:1990 01 1990 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $132,453 $678,000 Not Implemented
OK0303 # 02 Y:1990 02 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,621 $9,954 Implemented