Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,571

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0487 # 05 Y:2020 05 2020 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,823 $10,000 Implemented
LE0487 # 06 Y:2020 06 2020 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $399 $975 Implemented
LE0487 # 07 Y:2020 07 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,408 $16,552 Implemented
LE0487 # 08 Y:2020 08 2020 PREHEAT COMBUSTION AIR WITH WASTE HEAT $27,628 $85,000 Not Implemented
LE0487 # 09 Y:2020 09 2020 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $4,451 $15,000 Implemented
LE0487 # 10 Y:2020 10 2020 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,832 $8,000 Implemented
LE0487 # 11 Y:2020 11 2020 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,929 $30,000 Implemented
TR0021 # 01 Y:2020 01 2020 INSTALL OCCUPANCY SENSORS $183 $210 Not Implemented
TR0021 # 02 Y:2020 02 2020 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $35,728 $7,275 Implemented
TR0021 # 04 Y:2020 04 2020 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,409 $0 Not Implemented
UF0544 # 01 Y:2020 01 2020 USE SOLAR HEAT TO MAKE ELECTRICTY $53,586 $333,760 Implemented
UF0544 # 02 Y:2020 02 2020 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $46,696 $42,592 Implemented
UF0544 # 03 Y:2020 03 2020 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $30,318 $90,000 Implemented
UF0544 # 04 Y:2020 04 2020 TURN OFF EQUIPMENT WHEN NOT IN USE $12,417 $913 Implemented
UF0544 # 05 Y:2020 05 2020 REDUCE DELIVERY SCHEDULES $2,082 $2,730 Not Implemented
UF0544 # 06 Y:2020 06 2020 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,023 $812 Implemented
MI0366 # 01 Y:2020 01 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $50,590 $93,076 Not Implemented
MI0366 # 02 Y:2020 02 2020 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,035 $1,115 Not Implemented
MI0366 # 03 Y:2020 03 2020 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,152 $120 Not Implemented
MI0366 # 04 Y:2020 04 2020 USE PHOTOCELL CONTROLS $3,435 $4,831 Not Implemented
MI0366 # 05 Y:2020 05 2020 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $3,258 $2,265 Not Implemented
MI0366 # 06 Y:2020 06 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,463 $1,980 Not Implemented
MI0366 # 07 Y:2020 07 2020 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,903 $4,341 Not Implemented
MI0366 # 08 Y:2020 08 2020 INSTALL OCCUPANCY SENSORS $1,690 $1,188 Not Implemented
OR0732 # 01 Y:2020 01 2020 INSULATE BARE EQUIPMENT $26,977 $0 Not Implemented