Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,516

matching recommendations
Reset
ARC 2. ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0131 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,722 $1,050 Implemented
AS0131 # 05 Y:1994 05 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,182 $6,400 Implemented
AS0131 # 06 Y:1994 06 1994 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $2,803 $990 Implemented
CO0316 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,280 $6,120 Implemented
CO0316 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,900 $7,530 Implemented
CO0316 # 08 Y:1994 08 1994 INSULATE BARE EQUIPMENT $2,710 $1,850 Implemented
IA0096 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,198 $350 Implemented
IA0096 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,536 $7,244 Implemented
IA0096 # 08 Y:1994 08 1994 INSTALL OCCUPANCY SENSORS $448 $1,067 Implemented
OK0452 # 01 Y:1994 01 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $17,658 $12,000 Implemented
OK0452 # 02 Y:1994 02 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $9,302 $0 Implemented
OK0452 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $790 $1,351 Implemented
MA0319 # 02 Y:1994 02 1994 OPTIMIZE PLANT POWER FACTOR $5,357 $12,000 Implemented
NC0040 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $659 $480 Implemented
NC0040 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $723 $360 Implemented
NC0040 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $807 $1,190 Implemented
ND0194 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $23,523 $21,380 Implemented
ND0194 # 03 Y:1994 03 1994 OPTIMIZE PLANT POWER FACTOR $21,631 $30,688 Implemented
ND0194 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,162 $7,693 Implemented
ND0194 # 08 Y:1994 08 1994 REPAIR OR REPLACE STEAM TRAPS $2,707 $2,500 Implemented
ND0194 # 09 Y:1994 09 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,576 $200 Implemented
ND0194 # 11 Y:1994 11 1994 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $346 $150 Implemented
ND0203 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,176 $5,530 Implemented
ND0203 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,325 $5,045 Implemented
ND0203 # 05 Y:1994 05 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,350 $200 Implemented