Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,412

matching recommendations
Reset
ARC 2. ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0237 # 05 Y:2003 05 2003 AIR CONDITION ONLY SPACE NECESSARY $1,466 $800 Not Implemented
MS0237 # 06 Y:2003 06 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,210 $654 Not Implemented
MS0237 # 07 Y:2003 07 2003 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $430 $752 Implemented
IC0070 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,895 $46,610 Not Implemented
IC0070 # 02 Y:2003 02 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,127 $2,716 Not Implemented
IC0070 # 03 Y:2003 03 2003 INSTALL OCCUPANCY SENSORS $8,874 $22,864 Not Implemented
IC0070 # 04 Y:2003 04 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $51,638 $160,788 Not Implemented
IC0070 # 05 Y:2003 05 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,377 $0 Not Implemented
IC0070 # 06 Y:2003 06 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $56,367 $4,200 Implemented
IC0070 # 07 Y:2003 07 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $58,133 $0 Implemented
IC0070 # 08 Y:2003 08 2003 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $73,846 $613,200 Not Implemented
UU0055 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $710 $710 Not Implemented
UU0055 # 02 Y:2003 02 2003 ADD AREA LIGHTING SWITCHES $659 $500 Not Implemented
UU0055 # 03 Y:2003 03 2003 RECOVER WASTE HEAT FROM EQUIPMENT $430 $1,870 Not Implemented
UU0055 # 04 Y:2003 04 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $889 $349 Not Implemented
UU0055 # 05 Y:2003 05 2003 USE HEAT PUMP FOR SPACE CONDITIONING $2,492 $39,000 Not Implemented
UU0055 # 06 Y:2003 06 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,273 $7,500 Not Implemented
UU0055 # 07 Y:2003 07 2003 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $12,956 $21,000 Not Implemented
MA0544 # 01 Y:2003 01 2003 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $3,663 $2,000 Implemented
MA0544 # 02 Y:2003 02 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $2,425 $2,000 Not Implemented
MA0544 # 03 Y:2003 03 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,646 $6,156 Implemented
MA0544 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $1,236 $600 Not Implemented
MA0544 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $543 $20 Implemented
CO0533 # 01 Y:2003 01 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,350 $8,010 Not Implemented
CO0533 # 02 Y:2003 02 2003 INSULATE BARE EQUIPMENT $1,540 $740 Implemented