Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,575
matching recommendationsARC | 2. | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0365 # 11 Y:2009 | 11 | 2009 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $74,498 | $10,000 | Not Implemented |
BD0365 # 12 Y:2009 | 12 | 2009 | INSTALL TURBULATORS | $49,164 | $2,500 | Not Implemented |
BD0365 # 13 Y:2009 | 13 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $23,508 | $5,200 | Not Implemented |
SD0419 # 01 Y:2009 | 01 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,800 | $10,000 | Implemented |
SD0419 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,170 | $1,000 | Implemented |
SD0419 # 03 Y:2009 | 03 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $7,840 | $10,000 | Not Implemented |
SD0419 # 04 Y:2009 | 04 | 2009 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,940 | $2,263 | Implemented |
SD0419 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,905 | $161,162 | Implemented |
SD0419 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $39,102 | $50,136 | Not Implemented |
SD0419 # 07 Y:2009 | 07 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $14,906 | $500 | Not Implemented |
AM0563 # 01 Y:2009 | 01 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $29,000 | $52,000 | Not Implemented |
AM0563 # 02 Y:2009 | 02 | 2009 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $6,577 | $3,720 | Not Implemented |
AM0563 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,075 | $1,260 | Implemented |
AM0563 # 04 Y:2009 | 04 | 2009 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,040 | $1,134 | Not Implemented |
AM0563 # 05 Y:2009 | 05 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $885 | $610 | Not Implemented |
UM0357 # 01 Y:2009 | 01 | 2009 | INSTALL STORM WINDOWS AND DOORS | $88,261 | $361,980 | Implemented |
UM0357 # 02 Y:2009 | 02 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $48,733 | $25,000 | Implemented |
UM0357 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,053 | $42,818 | Implemented |
UM0357 # 04 Y:2009 | 04 | 2009 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $5,524 | $2,591 | Implemented |
UM0357 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,523 | $1,359 | Implemented |
UM0357 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $1,466 | $4,692 | Implemented |
UM0357 # 07 Y:2009 | 07 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,875 | $7,500 | Implemented |
GT0868 # 01 Y:2009 | 01 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $27,075 | $19,000 | Not Implemented |
GT0868 # 02 Y:2009 | 02 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,414 | $3,000 | Not Implemented |
GT0868 # 03 Y:2009 | 03 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,079 | $12,000 | Not Implemented |