Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

143,515

matching recommendations
Reset
ARC 2. ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0215 # 05 Y:1984 05 1984 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $341 $539 Not Implemented
GT0215 # 06 Y:1984 06 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $437 $1,000 Implemented
GT0215 # 07 Y:1984 07 1984 COVER OPEN TANKS $817 $2,000 Implemented
GT0217 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $20,387 $200 Implemented
GT0217 # 02 Y:1984 02 1984 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $11,700 $10,000 Implemented
GT0217 # 03 Y:1984 03 1984 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $188,200 $270,000 Not Implemented
GT0217 # 04 Y:1984 04 1984 MODIFY TEXTILE DRYERS $51,600 $23,000 Not Implemented
GT0217 # 05 Y:1984 05 1984 REPAIR AND ELIMINATE STEAM LEAKS $19,960 $1,000 Implemented
GT0217 # 06 Y:1984 06 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $1,670 $640 Implemented
GT0217 # 07 Y:1984 07 1984 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,040 $400 Not Implemented
GT0217 # 08 Y:1984 08 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,890 $2,520 Not Implemented
GT0222 # 01 Y:1984 01 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,190 $6,000 Implemented
OK0140 # 01 Y:1984 01 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $7,878 $0 Not Implemented
OK0140 # 02 Y:1984 02 1984 OPTIMIZE PLANT POWER FACTOR $1,129 $2,590 Not Implemented
OK0140 # 03 Y:1984 03 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,016 $0 Not Implemented
OK0140 # 04 Y:1984 04 1984 TURN OFF EQUIPMENT WHEN NOT IN USE $7,700 $2,500 Not Implemented
OK0140 # 05 Y:1984 05 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $698 $126 Implemented
OK0142 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $164 $268 Implemented
OK0142 # 02 Y:1984 02 1984 REDUCE VENTILATION AIR $125 $0 Implemented
OK0142 # 03 Y:1984 03 1984 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $100 $81 Not Implemented
OK0142 # 04 Y:1984 04 1984 INSULATE BARE EQUIPMENT $488 $58 Implemented
OK0143 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $260 $500 Implemented
OK0143 # 02 Y:1984 02 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $298 $105 Implemented
OK0143 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $604 $0 Implemented
OK0143 # 04 Y:1984 04 1984 INSULATE BARE EQUIPMENT $3,375 $1,950 Not Implemented