Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,210

matching recommendations
Reset
ARC 2. ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0398 # 05 Y:2010 05 2010 RECOVER WASTE HEAT FROM EQUIPMENT $1,751 $14,000 Not Implemented
NC0398 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,554 $1,205 Implemented
NC0398 # 07 Y:2010 07 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $93,642 $225,498 Implemented
MA0655 # 01 Y:2010 01 2010 INSULATE BARE EQUIPMENT $10,631 $32,201 Not Implemented
MA0655 # 02 Y:2010 02 2010 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $4,912 $18,270 Not Implemented
MA0655 # 03 Y:2010 03 2010 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,768 $200 Implemented
MA0655 # 04 Y:2010 04 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $1,570 $4,500 Not Implemented
MA0655 # 05 Y:2010 05 2010 INSTALL OCCUPANCY SENSORS $534 $2,640 Not Implemented
MS0348 # 01 Y:2010 01 2010 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $112,791 $264,425 Not Implemented
MS0348 # 02 Y:2010 02 2010 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $30,120 $217,605 Not Implemented
MS0348 # 03 Y:2010 03 2010 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $29,394 $103,215 Not Implemented
MS0348 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,319 $50,244 Not Implemented
MS0348 # 05 Y:2010 05 2010 INSTALL OCCUPANCY SENSORS $5,041 $300 Not Implemented
MS0348 # 06 Y:2010 06 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,658 $2,310 Not Implemented
MS0348 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,423 $378 Not Implemented
NC0397 # 01 Y:2010 01 2010 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $12,960 $17,280 Not Implemented
NC0397 # 02 Y:2010 02 2010 RECOVER WASTE HEAT FROM EQUIPMENT $712 $1,000 Not Implemented
NC0397 # 03 Y:2010 03 2010 INSULATE BARE EQUIPMENT $1,212 $3,660 Not Implemented
NC0397 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $492 $751 Not Implemented
NC0397 # 05 Y:2010 05 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,804 $12,206 Implemented
NC0397 # 06 Y:2010 06 2010 INSTALL OCCUPANCY SENSORS $399 $100 Implemented
BD0368 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,866 $25,159 Implemented
BD0368 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $1,960 $750 Not Implemented
BD0368 # 03 Y:2010 03 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $329 $410 Implemented
BD0368 # 04 Y:2010 04 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,981 $7,700 Not Implemented