Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,749
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0067 # 03 Y:1986 | 03 | 1986 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $484 | $900 | Implemented |
MA0069 # 01 Y:1986 | 01 | 1986 | REPAIR OR REPLACE STEAM TRAPS | $18,897 | $1,040 | Implemented |
OK0207 # 04 Y:1986 | 04 | 1986 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,124 | $8,200 | Implemented |
OK0207 # 05 Y:1986 | 05 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,466 | $1,200 | Implemented |
GT0292 # 02 Y:1986 | 02 | 1986 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $18,800 | $15,000 | Implemented |
GT0292 # 04 Y:1986 | 04 | 1986 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $15,300 | $22,400 | Implemented |
GT0293 # 02 Y:1986 | 02 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $65,300 | $75,000 | Implemented |
GT0293 # 06 Y:1986 | 06 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,330 | $3,045 | Implemented |
KU0201 # 05 Y:1986 | 05 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $1,243 | $90 | Implemented |
KU0201 # 07 Y:1986 | 07 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $740 | $10 | Implemented |
KU0198 # 02 Y:1986 | 02 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $17,771 | $880 | Implemented |
KU0198 # 04 Y:1986 | 04 | 1986 | USE MINIMUM STEAM OPERATING PRESSURE | $2,706 | $5,000 | Implemented |
KU0200 # 07 Y:1986 | 07 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $116 | $150 | Implemented |
GT0287 # 08 Y:1986 | 08 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,456 | $35,000 | Implemented |
GT0288 # 06 Y:1986 | 06 | 1986 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $13,970 | $20,000 | Implemented |
GT0289 # 05 Y:1986 | 05 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $5,410 | $500 | Implemented |
CO0061 # 10 Y:1986 | 10 | 1986 | INSULATE BARE EQUIPMENT | $695 | $620 | Implemented |
CO0063 # 02 Y:1986 | 02 | 1986 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $5,704 | $2,100 | Implemented |
CO0063 # 10 Y:1986 | 10 | 1986 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $339 | $750 | Implemented |
UD0199 # 01 Y:1986 | 01 | 1986 | USE MINIMUM STEAM OPERATING PRESSURE | $7,787 | $20,000 | Implemented |
UD0199 # 03 Y:1986 | 03 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,090 | $600 | Implemented |
UD0200 # 03 Y:1986 | 03 | 1986 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,924 | $3,000 | Implemented |
UD0200 # 06 Y:1986 | 06 | 1986 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,955 | $1,500 | Implemented |
UD0201 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,035 | $11,000 | Implemented |
ST0060 # 05 Y:1986 | 05 | 1986 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $134,226 | $93,000 | Implemented |