Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,645
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0055 # 03 Y:1982 | 03 | 1982 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,901 | $4,000 | Not Implemented |
OK0055 # 04 Y:1982 | 04 | 1982 | REDUCE GLAZED AREAS IN BUILDINGS | $2,354 | $3,036 | Not Implemented |
OK0037 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,647 | $552 | Not Implemented |
OK0037 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $749 | $1,484 | Not Implemented |
OK0038 # 02 Y:1982 | 02 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $23,027 | $29,970 | Not Implemented |
OK0038 # 04 Y:1982 | 04 | 1982 | INSTALL STORM WINDOWS AND DOORS | $4,750 | $17,358 | Not Implemented |
OK0040 # 01 Y:1982 | 01 | 1982 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,020 | $2,680 | Implemented |
OK0040 # 02 Y:1982 | 02 | 1982 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $1,682 | $4,000 | Implemented |
OK0040 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,994 | $922 | Implemented |
OK0045 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $150 | $147 | Not Implemented |
OK0045 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $67 | $200 | Not Implemented |
OK0050 # 05 Y:1982 | 05 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $275 | $790 | Not Implemented |
OK0054 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $5,398 | $100 | Not Implemented |
OK0054 # 03 Y:1982 | 03 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $644 | $100 | Not Implemented |
OK0054 # 04 Y:1982 | 04 | 1982 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,457 | $0 | Not Implemented |
OK0054 # 05 Y:1982 | 05 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,550 | $7,500 | Not Implemented |
OK0054 # 06 Y:1982 | 06 | 1982 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $258 | $0 | Not Implemented |
OK0054 # 07 Y:1982 | 07 | 1982 | INSTALL STORM WINDOWS AND DOORS | $449 | $572 | Not Implemented |
OK0054 # 09 Y:1982 | 09 | 1982 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,261 | $4,000 | Not Implemented |
OK0057 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $761 | $2,402 | Not Implemented |
OK0057 # 06 Y:1982 | 06 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $4,092 | $1,100 | Implemented |
TN0122 # 03 Y:1982 | 03 | 1982 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $663 | $800 | Not Implemented |
TN0124 # 01 Y:1982 | 01 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $1,715 | $8,360 | Not Implemented |
TN0124 # 02 Y:1982 | 02 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,333 | $1,080 | Not Implemented |
TN0124 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,101 | $11,060 | Not Implemented |