Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,685
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0165 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $3,077 | $2,400 | Not Implemented |
BD0165 # 04 Y:2000 | 04 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,226 | $8,000 | Not Implemented |
BD0165 # 05 Y:2000 | 05 | 2000 | SELL USED PLATES TO AN ALUMINUM RECYCLER | $1,863 | $600 | Implemented |
BD0165 # 06 Y:2000 | 06 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $280 | $600 | Not Implemented |
BD0166 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,357 | $2,000 | Not Implemented |
BD0166 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $2,182 | $2,700 | Implemented |
BD0166 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,263 | $0 | Not Implemented |
BD0166 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $823 | $500 | Implemented |
BD0166 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $594 | $1,000 | Not Implemented |
BD0166 # 06 Y:2000 | 06 | 2000 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $380,939 | $600,000 | Not Implemented |
BD0166 # 07 Y:2000 | 07 | 2000 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $33,228 | $35,000 | Implemented |
BD0166 # 08 Y:2000 | 08 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $6,646 | $2,000 | Not Implemented |
BD0166 # 09 Y:2000 | 09 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,759 | $6,500 | Implemented |
BD0166 # 10 Y:2000 | 10 | 2000 | REPAIR AND ELIMINATE STEAM LEAKS | $997 | $600 | Implemented |
BD0158 # 01 Y:2000 | 01 | 2000 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $17,993 | $20,000 | Not Implemented |
BD0158 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $4,276 | $1,650 | Not Implemented |
BD0158 # 03 Y:2000 | 03 | 2000 | INSTALL AUTOMATIC STACK DAMPER | $1,929 | $3,000 | Implemented |
BD0158 # 04 Y:2000 | 04 | 2000 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $13,680 | $5,000 | Not Implemented |
BD0158 # 05 Y:2000 | 05 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $600 | $240 | Implemented |
BD0158 # 06 Y:2000 | 06 | 2000 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $631,800 | $50,000 | Implemented |
BD0162 # 01 Y:2000 | 01 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,293 | $14,000 | Not Implemented |
BD0162 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $709 | $800 | Not Implemented |
BD0162 # 03 Y:2000 | 03 | 2000 | REPAIR AND ELIMINATE STEAM LEAKS | $270 | $150 | Implemented |
BD0162 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $247 | $172 | Not Implemented |
BD0162 # 05 Y:2000 | 05 | 2000 | USE EVAPORATION TO CONCENTRATE MATERIAL | $13,419 | $10,000 | Implemented |