Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,391
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0410 # 01 Y:2012 | 01 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,500 | $5,500 | Not Implemented |
BD0410 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,850 | $20 | Not Implemented |
BD0410 # 03 Y:2012 | 03 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $821 | $10,000 | Not Implemented |
BD0410 # 04 Y:2012 | 04 | 2012 | USE PHOTOCELL CONTROLS | $4,755 | $4,050 | Not Implemented |
BD0410 # 05 Y:2012 | 05 | 2012 | USE SYNTHETIC LUBRICANT | $3,095 | $1,000 | Not Implemented |
BD0408 # 01 Y:2012 | 01 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $23,702 | $57,000 | Not Implemented |
BD0408 # 02 Y:2012 | 02 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $15,937 | $1,500 | Implemented |
BD0408 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,611 | $50 | Not Implemented |
BD0408 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,622 | $4,000 | Implemented |
BD0408 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $154 | $20 | Implemented |
BD0408 # 06 Y:2012 | 06 | 2012 | RECOVER AND REUSE WASTE MATERIAL | $975 | $400 | Implemented |
BD0407 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,152 | $4,550 | Implemented |
BD0407 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,651 | $2,474 | Implemented |
BD0407 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $2,441 | $1,125 | Not Implemented |
BD0407 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,629 | $10 | Not Implemented |
BD0407 # 05 Y:2012 | 05 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,259 | $1,420 | Not Implemented |
BD0407 # 06 Y:2012 | 06 | 2012 | USE PHOTOCELL CONTROLS | $281 | $300 | Not Implemented |
BD0406 # 01 Y:2012 | 01 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $31,639 | $4,573 | Not Implemented |
BD0406 # 02 Y:2012 | 02 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,397 | $800 | Not Implemented |
BD0406 # 03 Y:2012 | 03 | 2012 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $12,730 | $10,000 | Not Implemented |
BD0406 # 04 Y:2012 | 04 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,394 | $3,000 | Implemented |
BD0406 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,151 | $7,591 | Not Implemented |
BD0406 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,404 | $500 | Implemented |
BD0406 # 07 Y:2012 | 07 | 2012 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $2,394 | $9,400 | Not Implemented |
BD0406 # 08 Y:2012 | 08 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,126 | $3,350 | Not Implemented |