Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,685
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0368 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $1,960 | $750 | Not Implemented |
BD0368 # 03 Y:2010 | 03 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $329 | $410 | Implemented |
BD0368 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,981 | $7,700 | Not Implemented |
BD0368 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,297 | $2,500 | Not Implemented |
BD0368 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,857 | $0 | Implemented |
BD0367 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,090 | $19,121 | Not Implemented |
BD0367 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $803 | $450 | Not Implemented |
BD0367 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $850 | $450 | Not Implemented |
BD0367 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $328 | $100 | Not Implemented |
BD0367 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,367 | $2,000 | Not Implemented |
BD0367 # 06 Y:2010 | 06 | 2010 | USE SYNTHETIC LUBRICANT | $10,513 | $1,000 | Not Implemented |
BD0367 # 07 Y:2010 | 07 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,960 | $0 | Not Implemented |
BD0367 # 08 Y:2010 | 08 | 2010 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $10,366 | $10,000 | Not Implemented |
BD0367 # 09 Y:2010 | 09 | 2010 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $7,942 | $8,000 | Not Implemented |
BD0367 # 10 Y:2010 | 10 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,935 | $8,000 | Not Implemented |
BD0367 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $7,420 | $3,130 | Not Implemented |
BD0367 # 12 Y:2010 | 12 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,145 | $3,600 | Not Implemented |
BD0367 # 13 Y:2010 | 13 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $27,993 | $39,800 | Not Implemented |
BD0367 # 14 Y:2010 | 14 | 2010 | MINIMIZE WATER USAGE | $1,884 | $3,920 | Not Implemented |
BD0366 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $9,620 | $210 | Implemented |
BD0366 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,837 | $2,700 | Implemented |
BD0366 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,342 | $1,000 | Not Implemented |
BD0366 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,922 | $0 | Not Implemented |
BD0366 # 05 Y:2010 | 05 | 2010 | IMPROVE LUBRICATION PRACTICES | $2,368 | $600 | Implemented |
BD0366 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,606 | $3,000 | Not Implemented |